Mitsubishi FR-A721-11K Instruction Manual page 124

Inverter fr-a701
Table of Contents

Advertisement

Parameter
Name
Second motor constant
458
(R1)
Second motor constant
459
(R2)
Second motor constant (L1)
460
Second motor constant (L2)
461
Second motor constant (X)
462
Second motor auto tuning
463
setting/status
Tuning data unit switchover
684
Torque current
859
Second motor torque
860
current
89
Refer to Pr. 81.
90 to 94
Refer to Pr. 82 to Pr. 84.
95
Online auto tuning selection
Second motor online auto
574
tuning
96
Refer to Pr. 82 to Pr. 84.
Incre
Initial
Range
ments
Value
Tuning data of the second motor
0 to 50Ω
(The value measured by offline auto tuning is
automatically set.)
0.001Ω
9999
Use the Mitsubishi motor (SF-JR, SF-HR, SF-JRCA,
9999
SF-HRCA, SF-V5RU (1500r/min series)) constants
Tuning data of the second motor
0 to 50Ω
(The value measured by offline auto tuning is
automatically set.)
0.001Ω
9999
Use the Mitsubishi motor (SF-JR, SF-HR, SF-JRCA,
9999
SF-HRCA, SF-V5RU (1500r/min series)) constants
Tuning data of the second motor
0 to 50Ω (0
(The value measured by offline auto tuning is
0.001Ω
to 1000mH)
automatically set.)
9999
(0.1mH)
Use the Mitsubishi motor (SF-JR, SF-HR, SF-JRCA,
9999
SF-HRCA, SF-V5RU (1500r/min series)) constants
Tuning data of the second motor
0 to 50Ω (0
(The value measured by offline auto tuning is
0.001Ω
to 1000mH)
automatically set.)
9999
(0.1mH)
Use the Mitsubishi motor (SF-JR, SF-HR, SF-JRCA,
9999
SF-HRCA, SF-V5RU (1500r/min series)) constants
Tuning data of the second motor
0 to 500Ω
(The value measured by offline auto tuning is
0.01Ω
(0 to 100%)
automatically set.)
9999
(0.1%)
Use the Mitsubishi motor (SF-JR, SF-HR, SF-JRCA,
9999
SF-HRCA, SF-V5RU (1500r/min series)) constants
Set the tuning mode of the second motor. (same as
1
0
0, 1, 101
Pr. 96)
0
Internal data converter value
1
0
Displayed in "A, Ω, mH, %".
1
Tuning data
0 to 500A
(The value measured by offline auto tuning is
automatically set.)
0.01A
9999
Use the Mitsubishi motor (SF-JR, SF-HR, SF-JRCA,
9999
SF-HRCA, SF-V5RU (1500r/min series)) constants
Tuning data of the second motor
0 to 500A
(The value measured by offline auto tuning is
automatically set.)
0.01A
9999
Use the Mitsubishi motor (SF-JR, SF-HR, SF-JRCA,
9999
SF-HRCA, SF-V5RU (1500r/min series)) constants
0
Online auto tuning is not performed
1
0
1
Start-time tuning (at start-up)
2
Magnetic flux observer (normal)
Select the second motor online auto tuning. (same as
1
0
0, 1
Pr. 95)
Parameter List
Description
117
4

Advertisement

Table of Contents