• a=116: Sets the paper specified by (nL+nH×256).
(nL+nH×256)
1(Default)
Specified single color paper.
Recommended 2-color
257
paper5
• a=151: Sets the Bluetooth Security/Connect Device specified
by (nL+nH×256). [CT-S601II, CT-S651II]
(nL+nH×256)
Security / Connect Device
1(Default)
Low / All
2
Middle / All
3
Middle / Paired
4
High / All
5
High / Paired
• a=155: Sets the Bluetooth device scan specified by (nL+nH×256).
[CT-S601II, CT-S651II]
(nL+nH×256)
BT Device Scan
1
No Response
2(Default)
Discoverable
• a=156: Sets the Bluetooth Auto Reconnect request specified
by (nL+nH×256). [CT-S601II, CT-S651II]
(nL+nH×256)
Auto Reconnect
1
2(Default)
CT-S300
CT-S2000
CT-S4000
CT-S310
CT-S801/851
CT-S601/651
Paper
Invalid
Valid
CT-S251
CT-D150/E351
CT-P29x series
CT-S310II
• a=201: Outputs ACK to the position specified by (nL+nH×256).
(nL+nH×256)
1(Default)
2
3
• a=202: Controls input buffer full Busy with the value selected by
(nL+nH×256) and controls Busy with output/cancel timing
(remaining capacity).
(nL+nH×256)
1(Default)
2
3
4
• XON/XOFF is also output by the establishment of conditions.
• Ignores the data received when input buffer idle capacity is 0.
• a=212: Selects DMA (Direct Memory Access) control of serial
communication specified by (nL+nH×256).
(nL+nH×256)
1
2(Default)
- 269 -
ACK Output Position
ACK-in-Busy
ACK-while-Busy
ACK-after-Busy
When Input Buffer
When Input Buffer
Capacity 4K Bytes (Large)
Capacity "Small" is Set
Output
Cancel
Output
16
26
128
16
40
128
30
50
72
30
60
72
DMA control
Invalid
Valid
is Set
Cancel
256
512
256
512