Dimplex LA 6S-TUR Installation And Operating Instructions Manual page 28

Air-to-water heat pump for outdoor installation

Advertisement

Available languages

Available languages

English
6
Electrical connection
6.1
Supply voltage / fusing / RCD type
6.2
Control voltage / fusing via WPM
6.3
Degree of protection according to EN 60529
6.4
Starting current limiter
6.5
Rotary field monitoring
6.6
Starting current with soft starter
6.7
Nominal power consumption A2 / W35 / max. power consumption
6.8
Nominal current A2 /W35 / cos ϕ
6.9
Power consumption of compressor protection (per compressor)
6.10 Power consumption fan
7
Complies with the European safety regulations
8
Additional model features
8.1
Type of defrosting
8.2
Condensate tray frost protection / water in device is protected from freezing
8.3
Max. operating pressure (heat source/heat sink)
9
Heat output coefficient of performance (COP)
9.1
Heat output / COP
10
Cooling capacity / coefficient of performance (COP)
10.1 Cooling capacity / coefficient of performance (COP)
1. For air temperatures between -22°C and -5°C, flow temperature increasing from 45°C to 60°C.
2. This data indicates the size and capacity of the system according to EN 14511. For an analysis of the conomic and energy efficiency of the system, other parameters, in particular
the defrosting capacity and regulation, should also be taken into consideration. These figures are only achieved with clean heat exchangers. Instructions for care, commissioning
and operation can be found in the relevant sections of the installation and operation instructions. The specified values have the following meaning, e.g. A7/W35: outside air tem-
perature 7°C and heating water flow temperature 35°C.
3. The heat output and COP is reduced by approx. 5 % in lower operation.
4. The maximum sound power level under full load can increase by up to 5 dB(A), depending on the installation location.
5. The specified sound pressure level represents the free sound area level. The measured value can deviate by up to 16 dB(A), depending on the installation location.
6. see CE declaration of conformity
7. The heat circulating pump and the heat pump manager must always be ready for operation.
EN-12
2
2
with A-7 / W35
with A2 / W35
with A7 / W35
with A7 / W45
with A10 / W35
2 4
with A27 / W18
with A27 / W7
with A35 / W18
with A35 / W7
452163.66.65 · FD 9702
3~/N/PE 400 V (50 Hz) / C10 A / A
1~/N/PE 230 V (50 Hz) / 4 AT
A
kW
A / ---
W
W
7
bar
kW / ---
kW / ---
kW / ---
kW / ---
kW / ---
kW / ---
kW / ---
kW / ---
kW / ---
LA 6S-TU - LA 6S-TUR
IP 24
no
no
28
1,4 / 2,93
2,88 / 0,8
--
< 125
6
Reverse circulation
Yes
3,0
EN 14511
4,0 / 2,9
5,1 / 3,8
6,4 / 4,6
6,1 / 3,5
6,7 / 4,7
EN 14511
5,5 / 3,7
3,7 / 2,6
4,9 / 2,9
3,6 / 2,2
www.dimplex.de