Chapter 3 Disassembly and Maintenance
3-6. Disassembly, Reassembly and Lubrication
(2) Unit Power Supply
1. Remove the 2 screws (BH M3.0x4 (NI)) and detach the "Cover Power PCB".
2. Remove the 4 screws (PH (SW+PW) M3x5) and detach the "Unit Power Supply".
3. Remove the "Sheet Insulation Power PCB" from the "Plate Power PCB".
BH M3.0x4 (NI)
Plate Power PCB
(3) Plate Holder Paper L
1. Remove the 3 screws (BH M3.0x4 (NI)) and detach the "Cover Lever".
2. Remove the "SA Damper Shaft" and "Spring Damper" (2 pcs.) from the "Plate Holder
Paper L".
CL-E720DT
PH (SW+PW) M3x5
BH M3.0x4 (NI)
Cover Lever
Spring Damper
Cover Power PCB
Unit Power Supply
Sheet Insulation Power PCB
BH M3.0x4 (NI)
Spring Damper
SA Damper Shaft
Plate Holder Paper L