I I I I I EAN Non-PLU code format
Format table: Format 1 through Format 12
EAN-13 type
Flag
(02 or 20-29)
(1) Select the PGM2 mode and touch the [SETTING] to perform the programming.
(2) Touch the [ARTICLE] button to display the menu, and touch the [EAN NON-PLU] button to display the
format list.
(3) Touch or enter the format number and touch the [ENTER] key to program the format.
(4) Touch the required programming item, and enter or select each parameter and touch the [ENTER] key.
Repeat this step (4) satisfactorily.
(5) To terminate the programming, touch the [EXIT] key.
Text
TYPE OF CODE
SYSTEM CODE
LENGTH FIELD#1
LENGTH FIELD#2
FIELD#1 DATA
FIELD#2 DATA
PRICE CHECK DIGIT
TAB
(ARTICLE ➝ EAN NON-PLU ....... PGM2)
C
D
Free format
Price check digit
Field 1
Free format area
EAN8: EAN-8 format code
EAN13: EAN-13 format code
(UPC-A is "0n"of EAN13)
n:EAN8, nn:EAN13(UPC-A)
Length of field 1 (0 to 9)
Length of field 2 (0 to 9)
FREE (fixed "FREE")
Meaning of field 2
QUANTITY: quantity
PRICE: Price
Price Check digit
YES: Use the price check digit
NO: Not use the price check digit
TAB or decimal point of field 2 : 3/2/1/0
EAN-8 type
2
Free format
Flag
Field 2
Parameter
C
D
219