Wiring Diagrams - Goodman AVPTC42D14 series Installation & Operating Instructions Manual

Avptc**14 series
Table of Contents

Advertisement

27 Wiring Diagrams

WARNING
PL1
PL2
RD
2
2
3
3
BK
1
1
6
6
WH
BR
5
5
BL
4
4
7
7
8
8
9
9
4 CIRCUIT HEATER
SEE
NOTE 7
BK
SEE NOTE 6
RD
BL
GY
BK
RD
ECM MOTOR
HARNESS
NOTES:
1. PLACE RED WIRES ON TRANSFORMER TERMINAL 2 FOR 208 VAC OPERATION.
2. MANUFACTURER'S SPECIFIED REPLACEMENT PARTS MUST BE USED WHEN SERVICING.
3. IF ANY OF THE ORIGINAL WIRES AS SUPPLIED WITH THIS UNIT MUST BE REPLACED,
IT MUST BE REPLACED WITH WIRING MATERIAL HAVING A TEMPERATURE RATING OF AT
LEAST 105°C. USE COPPER CONDUCTORS ONLY.
4. UNIT MUST BE PERMANENTLY GROUNDED AND CONFORM TO N.E.C AND LOCAL CODES.
5. TO RECALL THE LAST 6 FAULTS, MOST RECENT TO LEAST RECENT, DEPRESS
SWITCH FOR MORE THAN 2 SECONDS WHILE IN STANDBY (NO THERMOSTAT INPUTS)
6. RED STATUS LED PROVIDES NETWORK STATUS. GREEN RX LED INDICATES NETWORK TRAFFIC.
USE LEARN BUTTON TO RESET NETWORK.
7. DISCARD CONNECTOR PL1 WHEN INSTALLING OPTIONAL HEAT KIT.
8. THE CONDENSATE ALARM SWITCH (CAS) TERMINALS CAN ONLY BE UTILIZED WITH COMMUNICATING
MODE SETUPS AND MUST BE ENABLED WITH A COMMUNICATING THERMOSTAT. THIS FEATURE IS NOT
OPERATIONAL WITH LEGACY SYSTEMS.
USE N.E.C CLASS 2 WIRE.
Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring.
HIGH VOLTAGE!
MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO DO SO
MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH.
40 VA TRANSFORMER, SEE NOTE 1
230 VAC
RD
3
RD
208 VAC
24 VAC
2
COM
1
BL
BK
W2 W1
C
CONNECTOR
LEARN
SEE NOTE 5
FAULT
SEE NOTE 6
RECALL
STATUS
LED
7 SEGMENT
DIAGNOSTIC
DISPLAY
CFM LED
4
SEE NOTE 6
RX LED
3
2
1
S1 S2 S3 S4
S5 S6 S7 S8
S9 S10 S11 S12 S13
DIP SWITCHES
TWO-STAGE INTEGRATED CONTROL MODULE
CIRCULATOR BLOWER
4 3 2 1
1
2
3
4
5
DISCONNECT ALL POWER BEFORE SERVICING.
GRND
GN
DISCONNECT
BL
RD
TR
TH
COM
24 V 3 A
FUSE
CAS
L1
SEE NOTE 8
DEHUM
FUSE 3 A
O
R
Y2
Y1
W1
W2
W1
W2
G
Y1
C
R
TO
Y2
MICRO
2
1
G
O
DEHUM
C
GN
GRND
RD
BK
INTEGRATED CONTROL
LOW VOLTAGE (24V)
LOW VOLTAGE FIELD
HI VOLTAGE (230V)
HI VOLTAGE FIELD
JUNCTION
TERMINAL
INTERNAL TO
EQUIPMENT GRND
FIELD GRND
FIELD SPLICE
RESISTOR
OVERCURRENT
PROT. DEVICE
PLUG CONNECTION
28
L1
L2
GRND
INDOOR
AIR
CIRCULATOR
BLWR
GRND
208/230 VAC
40 VA
TRANSFORMER
TH
24 VAC
W1 (1)
HEAT 1 COIL/R1
W2 (2)
HEAT 2 COIL/ R2
CAS (1)
CONDENSATE SWITCH
CAS (2)
+VDC (1)
RX (2)
INDOOR
TX (3)
CIRCULATOR
BLWR
GRND (4)
TR
COM
INTEGRATED CONTROL MODULE
COLOR CODES:
PK ---- PINK
BR ---- BROWN
WH ---- WHITE
BL ---- BLUE
GY ---- GRAY
RD ---- RED
YL ---- YELLOW
OR ---- ORANGE
PU ---- PURPLE
GN ---- GREEN
BK ---- BLACK
L2
AIR
GRND
0140A00244-B