Panasonic T-SMART DBS-EX23-530 Reference Manual page 90

Philips telephone user manual
Table of Contents

Advertisement

Special ISDN Function Codes
Parameter
Description
Execution
Options
Parameter
Description
Execution
Options
Parameter
Description
Execution
Options
4-38
Forced Re-synchronization
Re-synchronizes the DBS ISDN with the public network.
Notes:
1. Forced re-synchronization disconnects existing calls.
2. Before executing this code, you must first enter the program-
ming authorization code (#98 9999).
Master: ON/OFF #94 6
Slave: ON/OFF #95 6
None. Re-synchronization begins as soon as the code is entered.
Historical Error Clearance
Clears the error counters for the following alarms:
• yellow
• red
• framing loss
• slip rate
• loss of signal
• sync loss
Note: Before executing this code, you must first enter the pro-
gramming authorization code (#98 9999).
Master: ON/OFF #94 7
Slave: ON/OFF #95 7
None. The counters are cleared as soon as the code is entered.
Alarm Relay Clear
Clears (opens) the alarm relay on the ISDN MDF card.
Note: Before executing this code, you must first enter the pro-
gramming authorization code (#98 9999).
Master: ON/OFF #94 8
Slave: ON/OFF #95 8
None. The relay is cleared as soon as the code is entered.
DBS-EX23-530
Programming Reference
Revised April 2000

Advertisement

Table of Contents
loading