System-Wide Timers
Parameter
Description
Programming
Options
Parameter
Description
Programming
Options
4-8
Ringing Timer (T301)
Determines how long the called party will ring before the DBS will
disconnect the call.
FF1 9# 4# 2# 2# (0-15)#
0-10
0=180 sec.
1=20 sec.
2=40 sec.
3=60 sec.
.
.
.
11=220 sec.
12=240 sec.
13=240 sec.
14=240 sec.
15=Infinite
Call Setup Timer (T303)
Determines the time limit for a CO to respond to an outgoing call
attempt.
FF1 9# 4# 2# 3# (0-10)#
0-10
0=4 sec.
1=1 sec.
2=2 sec.
3=3 sec.
4=4 sec.
5=5 sec.
6=6 sec.
7=7 sec.
8=8 sec.
9=9 sec.
10=10 sec.
DBS-EX23-530