S
M
- VTM
YSTEM
ODE
Download
NOTE
50
355/
265 U
E
E
SER AND
5
Select 3 for Download.
6
Press ENTER to select default file group 1.
7
Enter file group default password 166831.
8
Press ENTER.
9
Press ENTER to select Single-app.
10
Press 2 to select Partial dnld.
11
Press 2 to select COM1 port.
12
Verify dongle connection to e355 and serial cable to PC.
13
Send command ddl -p# *UNZIP=NOVA-xx.xx.xx.zip NOVA-
xx.xx.xx.zip from PC to start download. Where # in -p# is the comm port
number of the serial device seen in the Device Manager on the PC.
14
After completion of download, press CANCEL to exit from download menu
and select restart to manually exit from VTM.
15
OS starts software installation process one component at a time. The
AUTHENTICATE message is displayed when signature and certificates are
verified, otherwise, FAILED message is displayed. Installation is incomplete
after a FAILED message.
Figure 18
e355 and PC Download via Serial (COM1) Port
If you are having problems selecting COM1 port on e355, check if configuration
variable *DEBUG=1 is set in Edit Parameters, either change *DEBUG value to 4 or
delete it.
If you are having difficulty starting ddl command in PC, check if some other
program in PC already has access to this comm port.
It is recommended to use partial download over full download for keeping the
same environment in the unit. Full downloads are recommended only at
deployment or repair facilities where unit is configured and verified.
B
P
G
EST
RACTICES
UIDE
Load e355 Nova Package
Please enter port #: 7
Opened COM7, 115200 baud
.....
Connected to E355 terminal
File
sponsorCert.crt
956 bytes
Config
*unzip=NOVA-01.A1.02.zip
File
Nova-01.A1.02.zip
0retry
963000