Example 1
Example 2
*3
The conversion speed indicates how long it takes the value of measured
temperature to be stored into the buffered memory at sampling. Regardless
of the number of channels permitting the conversion, the value of measured
temperature resulted from all channels is stored into the buffered memory
per 320ms.
*4
The output at detecting wire break has a choice among "Upscale",
"Downscale" and "Given value".
Pt100 detecting range: From -200
Ambient temperature of Pt100: 40
Resistance thermometer detectors: Class A of Pt100 detector
Measuring temperature: 800
(Degree of accuracy) = ( 2.4
The degree of conversion
accuracy at 40
ambient temperature
Pt100 detecting range: From -200
Ambient temperature of Pt100: 25
Resistance thermometer detector: Class B of Pt100 detector
Measuring temperature: 500
(Degree of accuracy) = ( 0.8
The degree of conversion
accuracy at 25
ambient temperature
to 850
) + { (0.15
+0.002 800
Pt100 tolerances at 800
, the
Class A detected
to 850
) + { (0.3
+0.005 500
Pt100 tolerances at 500
, the
Class B detected
4
)} =
4.15
)} =
3.6