15 SW Installation/Update and Data Backup
15.3 Data backup
15-498
Following menu:
PLEASE SELECT
1
Configure Ghost Parameters
2
Partitions Backup, Mode LOCAL
3
Partitions Restore, Mode LOCAL
4
Delete Image
9
Back to previous Menu
Your Choice [1,2,3,4,9]?
5. Choose the menu item Partitions Backup, Mode LOCAL using key "3".
Following menu:
PLEASE SELECT
1
PCU Basic Software V06.01.04 Win NT 4.0
[05.09.2000;05.30.32pm]
2
Start-up intermediate version 1
[05.10.2000; 04.03.15pm]
9
Back to previous Menu
Your Choice [1,2,9]?
6. The descriptions that have been specified for the individual partition back-
ups are displayed. Choose the partition backup you want to restore.
In the example: "Start-up intermediate version 1" using the key "2".
After confirmation, a warning is displayed:
CAUTION: All data will be overwritten!
If you confirm again, the partitions of the hard disk are restored.
Following menu:
It seems, that Ghost Restore succeeded.
Hit any Key to reboot the System.
When the PCU is booted for the next time under Windows NT, the partitions E:
and F: will be checked by the diagnostic program CHKDISK in succession
whereby the PCU is rebooted automatically.
After completion of the check, the system with the restored backup copy is
active.
 Siemens AG, 2003. All rights reserved
SINUMERIK 840Di Manual (HBI) – 06.03 Edition
06.03