Siemens SINUMERIK 840Di Manual page 282

Hide thumbs Also See for SINUMERIK 840Di:
Table of Contents

Advertisement

10 NC Start-Up with HMI Advanced
10.3 System data
Tip
Display resolution
Limit values for
input and
display
Machine data
Table 10-5
Resolutions: Machine data
Number
General ($MN_ ...)
9004
DISPLAY_RESOLUTION
9011
DISPLAY_RESOLUTION_INCH
10200
INT_INCR_PER_MM
10210
INT_INCR_PER_DEG
References
10-282
Computational resolution:
Programmed path:
Effective value =
To keep the executed rounding more traceable, it is reasonable to use powers
to the 10th for the computational resolution (100, 1000, 10.000).
In MD 9004: DISPLAY_RESOLUTION, you can set the number of decimal
places after the decimal point for the position values on the operator panel.
The limitation of the input limits depends on the display and input possibilities on
the operator panel.
This limit is reached at 10 digit positions plus decimal point plus sign.
Examples of programming in the
Supposed all linear axes of a machine will be programmed and traversed within
the range of values 0.1 ... 1,000mm.
To position exactly to 0.1mm, the computational resolution must be set to
10
4
incr. /mm.
Check MD 10200: INT_INCR_PER_MM = 10,000 [incr. /mm]:
Example of related parts program:
N20 G0 X 1.0000 Y 1.0000 ;
N25 G0 X 5.0002 Y 2.0003 ;
Identifier
Display resolution
Display resolution for INCH unit system
Computational resolution for linear positions
Computational resolution for angular positions
/FB/
Description of Functions – Basic Machine
G2 Velocities, Traversing Ranges, Accuracies,
Section: Input/display resolution, calculation resolution
1,000 increments/mm
97.3786mm
97.379mm
mm-range:
1
/
10
Axes move to position
X=1.0000mm, Y=1.0000mm;
Axes move to position
X=5.0002mm, Y=2.0003mm
Name/remarks
 Siemens AG, 2003. All rights reserved
SINUMERIK 840Di Manual (HBI) – 06.03 Edition
06.03
Ref.
G2
G2
G2
G2

Advertisement