Management Function; Password Setting; Management Setting - Fujitsu UTY-RVNUM Installation Manual

Hide thumbs Also See for UTY-RVNUM:
Table of Contents

Advertisement

1 ) Indoor room temperature sensor switching function
(Only for Wired remote controller)
The following settings are needed when use the control by Wired remote
controller temperature sensor.
Setting Description
No
Yes
* If setting No. is "00" :
Room temperature is controlled by the indoor unit temperature sensor.
* If setting No. is "01" :
Room temperature is controlled by either indoor unit temperature sensor
or remote controller unit sensor.
2 ) Setting record
Record the setting change in the following table.
Setting Description
Room temperature sensor
switching
After completing the FUNCTION SETTING, be sure to turn off the power
and turn it on again.

11. MANAGEMENT FUNCTION

Restricts the operations of following power-saving functions by non-author-
ized person, and helps more energy-efficient operation of the system.
With the password control, only the administrator can get access to the
function setting.
For the controlled functions, perform the setting change in "Management
function" screen.
Settings Items:
Function
Economy
Set temp. auto return
Set temp. range
(Set temp. auto return : Set temperature auto return)
(Set temp. range : Set temperature range)
For the details on each function, refer to "2-2. Setting items in Menu" in the
operating manual.

11.1. Password setting

Preset value of password is "0000"
Change the password as necessary so that the setting change cannot be
done by other than the administrator.
The changed password should be managed properly by the administrator.
A password (4-digit) required when setting up a Management function can
be changed.
1
When [Menu button] is pressed twice while "Monitor" screen is dis-
played, it switches to the "Submenu" screen.
If [Menu button] is pressed while the "Submenu" screen is displayed,
the display returns to the "Monitor" screen.
Submenu
Date and time
Screen
Filter sign
R.C. sensor control
Room temp. display
Back:
Monitor
2
When [Initial] is selected in [Submenu] screen, "Initial" screen is
displayed. Enter current password with the [Cursor button], and press
the [Enter button].
Submenu
Key lock select
Initial
Management
Back:
Monitor
En-9
( ...Factory setting)
Function No.
Setting No.
42
Setting No.
Timer
On timer
Off timer
Weekly timer
Auto-off timer
1/2
[
]
Mo 10:00AM
Off
Off
Setting:
2/2
Mo 10:00AM
[
]
Child lock
Setting:
3
Select [Password setting (Management)] in the "Initial" screen, and
press the [Enter button].
00
01
4
Enter current password.
With pressing the [Cursor button (Up/Down)], enter the number. When
you press the [Cursor button (Right)], the cursor moves to next digit.
After you enter the 4 digits, press the [Enter button].
-Note-
When you forget a password, please push a [Menu button] and the
[Cancel button] at the same time for 3 seconds. Screen switches to
"Enter new password" screen.
5
Enter new password with same procedure in step 4.
Password setting
Enter new password.
0
Cancel :

11.2. Management setting

Management setting is a function that restricts the operation of some func-
tions on this remote controller.
The functions to be restricted are set in this setting, but not in each functional
setting.
Example: To restrict Economy setting to [ON]
Set to [ON] on all the other signal source except this remote controller.
1
When [Menu button] is pressed twice while "Monitor" screen is dis-
played, it switches to the "Submenu" screen.
If [Menu button] is pressed while the "Submenu" screen is displayed,
the display returns to the "Monitor" screen.
2
When [Management] is selected in [Submenu] screen, "Management"
screen is displayed. Enter current password with the [Cursor button],
and press the [Enter button].
Submenu
2/2
[
]
Key lock select
Initial
Management
Back:
Monitor
-Note-
If the entered password is not correct, message "Password is not
correct" is displayed. Enter correct password.
Initial
Language
Temp. unit
Password setting (Management)
Back:
Setting:
Filter sign
Management
Password setting
Enter current password.
0
0
0
OK:
Cancel :
Initial
Mo 10:00AM
Language
Temp. unit
Password setting (Management)
0
0
0
Back:
OK:
Filter sign
Submenu
1/2
[
]
Date and time
Screen
Filter sign
R.C. sensor control
Room temp. display
Back:
Setting:
Monitor
Management
Mo 10:00AM
Child lock
Enter current password.
Setting:
Cancel :
Initial
Mo 10:00AM
English
°F
Mo 10:00AM
0
Mo 10:00AM
English
°F
Setting:
Management
Mo 10:00AM
Off
Off
Mo 10:00AM
0
0
0
0
OK:
Date and time

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents