Fujitsu UTY-RNRT Operation Manual

Wired remote controller
Table of Contents

Advertisement

Quick Links

OPERATION MANUAL
WIRED REMOTE CONTROLLER
(for air conditioner)
UTY-RNRT
MODEL:
PART No. 9373329831-02
Before using this product, read these instructions
thoroughly and keep this manual for future reference.

Advertisement

Table of Contents
loading

Summary of Contents for Fujitsu UTY-RNRT

  • Page 1 OPERATION MANUAL WIRED REMOTE CONTROLLER (for air conditioner) UTY-RNRT MODEL: Before using this product, read these instructions thoroughly and keep this manual for future reference. PART No. 9373329831-02...
  • Page 2: Table Of Contents

    OPERATION MANUAL Summer Time (Daylight Saving Time) Setting (for administrator) ..........17 PART NO. 9373329831-02 WIRED REMOTE CONTROLLER Preference (for administrator) ......17 3-8-1 Panel Calibration ............ 17 3-8-2 Backlight Setting ............ 18 Contents 3-8-3 Contrast Setting ............. 18 INTRODUCTION Initial Setting (for administrator)......18 ■...
  • Page 3 Screen structure Mode Comfort Cool Heat 2-2-1 Auto Cancel Cancel Set Temp. Air Flow Direction Setting 2-2-2 Setting Setting 26.0 26.0 Swing °C °C Individual Hold Cancel Back Timer Setting 2-2-3 On Timer [Disable] Auto Off Timer [Disable] Auto Off Timer [Disable] Cancel Back...
  • Page 4: Introduction

    INTRODUCTION ■ SYSTEM OUTLINE 1 Terminology ■ SAFETY PRECAUTIONS System related terms (♦ is for VRF system) • The “SAFETY PRECAUTIONS” indicated in the manual (a) VRF system ♦: contain important information pertaining to your safety. VRF (Variable Refrigerant Flow) is a large multi-split Be sure to observe them.
  • Page 5: Password Confi Guration

    Address related terms 3 Name of parts (m) Indoor unit address ♦: This is an ID individually assigned to each indoor unit. (n) Remote controller address: This is an ID individually assigned separately from the indoor unit address to indoor units which form an R.C. Group.
  • Page 6: Monitor

    1 MONITOR Mode mismatch. The mode which cannot operate simultaneously is selected. Refer to [1-1-2 Status display]. 1-1 Monitor The On Timer, Off Timer, or Auto Off Timer is set. 1-1-1 Monitor mode screen Refer to [3 SETTING] → [3-4 Timer Setting]. The weekly timer is set.
  • Page 7: Child Lock

    • R.C. Prohibition: Set Temp. Limited: The functions whose operation from this unit and Wireless Indoor unit temperature setting is limited by the Central type remote controller is prohibited by the Central Control- controller. ler are displayed by icons. The contents of each icon are as follows: Energy Saving Operation: The energy saving is set by the Energy Manager for Sys-...
  • Page 8: On And Off

    2 CONTROL 2-2-2 Set the Temperature (1) Touch the [Set Temp.] on the monitor mode screen. 2-1 On and Off (2) “Set Temp.” screen is displayed. Adjust the room tem- (1) Press the [On/Off ] button. perature with the [ ] or [ ]. Set Temp.
  • Page 9: Zone Individual Operation

    2-3-2 Zone Individual Operation 2-3-4 Set the Priority Sensor (1) Touch the [Zone Operation] on (1) Touch the [Priority Sensor] on Zone Select Zone Select the “Zone Select” screen. the “Zone Select” screen. Zone Zone Sensor Priority Sensor Priority Operation Operation Method Sensor...
  • Page 10: Setting

    3 SETTING (2) “Air Flow Direction Setting” Air Flow Direction Setting screen is displayed. When the [VT Setting] or [HZ Setting] is Setting Setting 3-1 Select the Setting Items touched, each setting screen is displayed. (1) Touch the [Menu] on the moni- Fri 10:00AM Back tor mode screen.
  • Page 11: Individual Hold

    3-3-3 Individual Hold • 3D fl ow cassette type The number of outlet port diff ers depending on the model. “Individual Hold” can be used only with cassette type indoor unit which supports this function. The air fl ow direction can Indoor Unit 1 (00-00) Indoor Unit 1 (00-00) Left...
  • Page 12: On Timer

    3-4-1 On Timer Off Timer Enable/Disable Fri 10:00AM (1) Touch the [On Timer] on the Timer Setting “Timer Setting” screen. When Enable/Disable [Disable] Enable On Timer [Disable] the “Password Verifi cation” Off Timer [Disable] Operation Stop Time [In 0.5 hr] Disable screen is displayed, enter the Auto Off Timer...
  • Page 13: Weekly Timer Setting (For Administrator)

    (13) Touch the [OK] on the “Time Time Range Setting Fri 10:00AM Range Setting” screen. The Time Range [Range Spec.] Auto Off Timer Operation Stop Time Fri 10:00AM Fri 10:00AM display returns to the “Auto Off After the Manual Operation Enable /Disable [Enable] Start Time...
  • Page 14: Schedule Setting

    (3) When the [OK] is touched, after a setting change screen NOTE is displayed, the display returns to the “Weekly Timer Setting screen format corresponds to the preference Setting” screen. of the “Display format Setting”. NOTE To disable use of a schedule already set , touch [None] at (8) Touch the [On/Off...
  • Page 15: Day Off Setting

    A bar is displayed above the Schedule 1 Setting Fri 10:00AM day of the week with a sched- Wed Thu Weekly Timer Setting Day Off Setting ule set. 08:00 AM On 28.0°c Enable Schedule [Schedule 1] 10:00 AM –– Cool 26.0°c 12:00 PM ––...
  • Page 16: Economy

    • Fan Control for Energy Saving* (for administrator): (6) Set the time and temperature Cool/Dry When the set temperature is reached during cooling by touching [ ] or [ ]. The Return Time Return Temp. operation, the fan operates intermittently and power is time can be set within the 10 28.0 saved.
  • Page 17: Anti Freeze (For Administrator)

    (6) Each setting screen is dis- Auto played. Set the temperature Lower Limit Upper Limit Auto Saving Enable/Disable Fri 10:00AM upper limit and lower limit by 18.0 30.0 Enable/Disable [Disable] Enable touching [ ] or [ ]. °C °C Absence Detection Time [In 30 min.] Disable Cancel...
  • Page 18: Fan Control For Energy Saving (For Administrator)

    When the [Back] on the “Human Sensor Setting” is When the item to be set is touched, the display switches touched, the display returns to the “Special Setting” to each setting screen. When each setting is complete screen. or canceled, the display returns to this screen. When [Back] is touched, the display returns to the “Main Menu”...
  • Page 19: Backlight Setting

    3-8-2 Backlight Setting 3-8-3 Contrast Setting (1) Touch the [Backlight Setting] (1) Touch the [Contrast Setting] on the “Preference” screen. Preference on the “Preference” screen. (2) “Contrast Setting” screen is displayed. Adjust the con- Panel Backlight Calibration Setting trast with [ ] or [ ]. Contrast Back Preference...
  • Page 20: Date Setting

    • RC Sensor Setting * (4) Set the date by touching [ ] Date Sun 12:00AM This setting uses the sensor of this unit to sense the or [ ]. Month Year room temperature. The room temperature can be When the [OK] is touched, the sensed at a position, closer to the person than the 2017 display returns to the “Date...
  • Page 21: Temp. Unit Setting

    (d) Space key (12) “Time Format” screen is Time Format Fri 10:00AM displayed. Select the desired (e) Backspace key 12:00–11:59 AM/PM format. Cursor keys 00:00–11:59 AM/PM When the [OK] is touched, the 00:00–23:59 display returns to the “Display Change the R.C. Group Name Cancel Format Setting”...
  • Page 22: Display Item Setting

    Password request to the setting item On/Off is set. (3) “Filter Sign” screen is displayed. Touch the [Visible] or [Invisible]. (5) Touch the [Change Setting] Password Setting on the “Password Setting” Change Password screen. Display Item Setting Filter Sign Change Setting Filter Sign [Visible] Visible...
  • Page 23 (4) “Sensor Selection” screen is (12) Touch the [Priority Sensor Set- Zone1 Page 1/ 4 Priority Sensor Page 1/ 4 displayed. This screen con- ting] to display “Priority Sensor Sensor2 Sensor1 tains up to 4 pages. Touch the Setting” screen. This screen Sensor3 Sensor2 [Next Page] or [Previous Page]...
  • Page 24: Maintenance (For Administrator)

    Sensor Name Setting Verifi cation, operation, and setting of the following con- tents are performed. (♦: for installer) (18) Touch the [Sensor Name Set- Zone Setting (*1: Items that indoor unit does not support are not dis- ting] in “Zone Name Setting” Zone Temp Sensor played.) Zone Group Setting...
  • Page 25: Setting Status List

    4 OPERATION TIPS 3-10-2 Setting Status List (1) Touch the [Setting Status List] 4-1 Selectable Modes (for VRF system) Maintenance Page 1/ 3 on the “Maintenance” screen. Setting Error History Status List There are restrictions on the selectable modes depending on the system confi...
  • Page 26: Outdoor Unit Priority Connection In Heat Pump System

    5-2 Specifi cations 18 to 30 °C (64 to 88 °F) or Cool/Dry* Model Name UTY-RNRT 20 to 30 °C (68 to 88 °F) Input voltage DC 12 V VRF system: 10 to 30 °C (48 to 88 °F)