8. Check

8.1

Thermistor Resistance Check

Check No.01
Disconnect the connectors of the thermistors from the PCB, and measure the resistance of each
thermistor using a multimeter.
The data is for reference purpose only.
Service Diagnosis
Thermistor temperature
°C
°F
–20
–4
–15
5
–10
14
–5
23
0
32
5
41
10
50
15
59
20
68
25
77
30
86
35
95
40
104
45
113
50
122
(R25°C (77°F) = 20 kΩ, B = 3950 K)
(kΩ)
150
100
Room temperature
thermistor
Multimeter
(R20505)
When the room temperature thermistor is soldered on a PCB, remove the PCB from the control
PCB to measure the resistance.
When the connector of indoor heat exchanger thermistor is soldered on a PCB, remove the
thermistor and measure the resistance.
Resistance (kΩ)
197.8
148.2
112.1
85.60
65.93
51.14
39.99
31.52
25.02
20.00
16.10
13.04
10.62
8.707
7.176
50
–15
0
15
30
5
32
59
86
Other thermistors
(˚C)
45
(˚F)
113
(R14467)
Multimeter
Resistance range
Check
(R23371)
191

Hide quick links: