Indoor Unit
Model
Rated Capacity
External Static Pressure
H
M
Airflow Rate
L
SL
Type
Fan
Motor Output
Speed
Air Filter
Running Current (Rated)
Power Consumption (Rated)
Power Factor (Rated)
Temperature Control
Dimensions (H × W × D)
Packaged Dimensions (H × W × D)
Weight (Mass)
Gross Weight (Gross Mass)
Sound Pressure
H / M / L / SL
Level
Heat Insulation
Liquid
Piping
Gas
Connections
Drain
Drawing No.
14
inAq (Pa)
565 (16.0)
523 (14.8)
cfm
(m³/min)
477 (13.5)
395 (11.2)
W
Steps
A
W
%
in. (mm)
in. (mm)
Lbs (kg)
Lbs (kg)
dB(A)
38 / 36 / 34 / 32
in. (mm)
in. (mm)
in. (mm)
CDXS24LVJU
Cooling
24 kBtu/h Class
0.16 (40)
Sirocco Fan
130
5 Steps, Quiet, Auto
Removable, Washable, Mildew Proof
0.79
160
90.3
Microcomputer Control
7-7/8 × 43-5/16 × 24-7/16 (200 × 1,100 × 620)
10-1/2 × 52-1/16 × 30-1/4 (266 × 1,323 × 768)
66 (30)
84 (38)
Both Liquid and Gas Pipes
φ 1/4 (φ 6.4)
φ 5/8 (φ 15.9)
VP20 (O.D. φ 1-1/32 (φ 26), I.D. φ 25/32 (φ 20))
3D080590
SiUS121630EA
60 Hz, 208 - 230 V
Heating
565 (16.0)
523 (14.8)
477 (13.5)
395 (11.2)
0.79
160
92.8
38 / 36 / 34 / 32
Conversion Formulae
kcal/h = kW × 860
Btu/h = kW × 3412
cfm = m³/min × 35.3
Specifications

Hide quick links:

Advertisement

Table of Contents
loading