Daikin CTXG09QVJUW Service Manual page 222

Multi-split type air conditioners 2/3/4mxs-n series
Hide thumbs Also See for CTXG09QVJUW:
Table of Contents

Advertisement

Trial Operation
1. Set to COOL or HEAT operation using the
2. Press and hold Cancel button for 4 seconds
3. Select
4. Press On/Off button within 10 seconds, and
5. Press Menu/OK button in the basic screen.
6. Select
7. After the operation of airflow direction is
8. Press and hold Cancel button for 4 seconds
9. Select
10.If the decoration panel has not been
210
With Wired Remote Controller (BRC1E73)
remote controller.
or longer. Service settings menu is
displayed.
Test Operation
settings menu, and press Menu/OK button.
Basic screen returns and "Test Operation"
is displayed at the bottom.
the test operation starts.
Monitor the operation of the indoor unit for a
minimum of 10 minutes. During test
operation, the indoor unit will continue to
cool/heat regardless of the temperature
setpoint and room temperature.
In the case of above-mentioned
procedures 3 and 4 in reverse order, test
operation can start as well.
Main menu is displayed.
Airflow Direction
menu and press Menu/OK button. Check
that airflow direction is actuated according
to the setting. For operation of airflow
direction setting, see the operation manual.
confirmed, press Menu/OK button.
Basic screen returns.
or longer in the basic screen.
Service settings menu is displayed.
Test Operation
settings menu, and press Menu/OK button.
Basic screen returns and normal operation
is conducted.
Test operation will stop automatically
after 15 ~ 30 minutes. To stop the
operation, press On/Off button.
installed, turn off the power after the test
operation.
Basic screen
1.
2.
Cool
Service Settings
in the service
3.
4.
5.
Main menu screen
6.
in the main
7.
8.
in the service
9.
Basic screen
Set to
68
Press and hold Cancel
F
button for 4 seconds or
longer during backlight lit.
menu screen
Press Menu/OK button.
Press On/Off button
(within 10 seconds).
Press Menu/OK button.
Press Menu/OK button.
Change the airflow
direction by using
(Up/Down) button.
Press Menu/OK button.
Press and hold Cancel
button for 4 seconds or
longer during backlight lit.
Press Menu/OK button.
Trial Operation and Field Settings
SiUS121630EA