Technical specifications
6.3 Technical specifications
Electromagnetic compatibility (EMC)
Emitted interference
Noise immunity:
Mains borne disturbance variables on
supply lines
Noise immunity on signal lines
Immunity to discharges of static electricity ± 4 kV, contact discharge (according to IEC 61000–4-2;
Immunity to RF interference
Magnetic field
Climatic conditions
Temperature
During operation
Storage/transport
Relative humidity
During operation
Storage/transport
74
EN 61000-6-3, EN 61000-3-2 Class D and EN 61000-3-3
± 2 kV; (according to IEC 61000-4-4; Burst)
± 1 kV; (according to IEC 61000-4-5; Surge sym./
line to line)
± 2 kV; (according to IEC 61000-4-5; Surge sym./
line to earth)
± 1 kV;
(to IEC 61000-4-4; burst; length < 30 m)
± 2 kV;
(to IEC 61000-4-4; burst; length > 30 m)
± 2 kV;
(acc. to IEC 61000-4-5; surge pulse/cable to ground;
length > 30 m)
ESD)
± 8 kV, air discharge (according to IEC 61000-4-2; ESD)
10 V/m with 80% amplitude modulation at 1 kHz,
in accordance with SPH 150 kHz to 80 MHz (to IEC
61000-4-6)
10 V/m with 80 % amplitude modulation with 1kHz,
80 MHz to 1000 MHz
(to IEC 61000-4-3)
3 V/m with 80% amplitude modulation at 1 kHz,
1.4 GHz - 2 GHz (acc. to IEC 61000-4-3)
1 V/m, with 80% amplitude modulation at 1 kHz,
2.0 GHz – 2.7 GHz (to IEC 61000-4-3)
In accordance with SPH 30 A/m, 50 Hz and 60 Hz (acc.
to IEC 61000-4-8)
tested to IEC 60068-2-1, IEC 60068-2-2
+ 5 °C to + 45 °C max. 10 °C/h (no condensation)
–20 °C to + 60 °C at max. 20 °C/h (no condensation)
tested to IEC 60068-2-78, IEC 60068-2-30,
IEC 60068-2-14
5% to 85% at 30°C/h (no condensation)
5% to 95% at 25°C/h (no condensation)