1-4. VIDEO OUT Level Check (VC-543 board)
Mode
Signal
Measurement Point
Measuring Instrument
Specified value
Checking method:
Order Page Address Data
1
2
3
4
A
HVR-Z5C/Z5E/Z5J/Z5N/Z5P/Z5U
VCR mode
No signal
VIDEO OUT plug of A/V Remote
connector (75 Ω terminated)
Oscilloscope
Sync level: A = 286 ± 18 mVp-p(NTSC)
A = 300 ± 18 mVp-p(PAL)
Burst level: B = 286 ± 18 mVp-p(NTSC)
B = 300 ± 18 mVp-p(PAL)
Procedure
Perform "Preparations"
Check the sync signal level
(A) to the specified value.
Check the burst signal level
(B) to the specified value.
Perform "Processing after
Complete Adjustment".
H
Fig. 6-3-5
1-5. Processing after Complete Adjustment
Perform the setting through the procedure mentioned below when
you finish the "S VIDEO, VIDEO OUT Adjustment".
Order Page Address Data
1
0
10
C
2
0F
(1C)
8
3
04
(18)
8
4
00
(18)
8
5
01
(18)
8
6
06
(18)
7
0
10
8
3
70
9
3
70
10
7
83
11
0
01
B
6-107
Procedure
01
00
Press PAUSE (Write) button.
80
Press PAUSE (Write) button.
00
Press PAUSE (Write) button.
00
Press PAUSE (Write) button.
00
Press PAUSE (Write) button.
00
10
Press PAUSE (Write) button.
Check the data changes to
"11".
00
00