Adjusting method:
Order Page Address Data
1
0
01
2
6
61
3
4
0
10
F
5
4A
(9F)
F
6
4B
(9F)
7
0
10
8
6
02
9
6
99
10
6
4D
11
6
64
12
0
10
E
13
10
(7E)
14
0
10
15
6
40
16
6
01
17
18
6
01
19
6
02
20
6
0C
Note 7: After adjustment, if the focusing to a subject located at
infinity failed, increase the ilIlluminance of the chart and
perform readjustment.
Note 8: For the bit values, refer to "6-4. SERVICE MODE", "4-
4. 3. Bit value discrimination".
Note 9: The adjustment data will be automatically input to page:
6F, address: 20 to 3F.
Note 10: The center line portion of chart should be in the AF de-
tection frame "A" at the TELE end.
AF Detection Frame Display
HVR-Z5C/Z5E/Z5J/Z5N/Z5P/Z5U
Procedure
01
01
Wait for 3 seconds.
09
83
80
(Note 10)
00
Check the data is "00".
Check the data is "00".
40
04
07
Set the bit value of bit1 is "0",
and press PAUSE (Write)
button. (Note 8)
00
01
13
Press PAUSE (Write) button.
Wait for 1 seconds.
27
Press PAUSE (Write) button.
Check the data changes to
"01".
Check the data is "00".
A
B
Fig. 6-1-8
Processing after Completing Adjustment:
Order Page Address Data
1
6
01
2
6
64
3
6
4D
4
6
40
5
0
10
E
6
10
(7E)
7
0
10
8
6
61
9
10
0
10
F
11
4A
(9F)
F
12
4B
(9F)
13
0
10
14
6
01
15
6
02
16
6
01
17
0
01
7-2. Optical Axis Adjustment
Correct the disorder of the center axis of the optical system.
Adjustment Page
Adjustment Address
Adjusting method:
1) Select page: 0, address: 01, and set data: 01.
2) Select page: 0, address: 10, and set data: 07.
3) Input the following data to page: F (7F), address: 30 to 3F.
Note: Press the PAUSE (Write) button of the adjustment remote com-
mander each time to set data.
Address
Data
30
00
31
00
32
00
33
00
34
00
35
00
36
00
37
00
38
00
39
00
3A
00
3B
00
3C
00
3D
00
3E
00
3F
00
4) Select page: 0, address: 10, and set data: 00.
5) Select page: 0, address: 01, and set data: 00.
6-28
Procedure
00
Press PAUSE (Write) button.
00
00
00
07
Set the bit value of bit1 is "1",
and press PAUSE (Write)
button. (Note 7)
00
00
Wait for 3 seconds.
09
00
00
00
25
Press PAUSE (Write) button.
Check the data changes to
"01".
00
Press PAUSE (Write) button.
00
RadarW
RadarW
RadarW
RadarW
RadarW
7F
30 to 3F

Advertisement