Sony HVR-Z5C Service Manual page 199

Digital hd video camera recorder
Hide thumbs Also See for HVR-Z5C:
Table of Contents

Advertisement

8.
Flange Back Check
(Using the flange back adjustment jig)
Subject
Measurement Point
Measuring Instrument
Specified value
Note 1: Check that the data of page: 0, address: 10 is "00".
Note 2: Check with the monitor larger than 40 inches.
Switch setting
1) POWER ......................................................... CAMERA mode
2) ND FILTER ...................................................................... OFF
3) REC FORMAT (Menu setting) ............................. HDV1080i
Checking method:
Order Page Address Data
1
2
0
01
3
6
01
4
6
61
5
6
6
2C
7
6
40
8
6
41
9
6
4D
10
6
01
11
12
Processing after Completing Adjustment:
Order Page Address Data
1
6
01
2
6
2C
3
6
40
4
6
41
5
6
4D
6
6
61
7
8
0
01
HVR-Z5C/Z5E/Z5J/Z5N/Z5P/Z5U
Flange back adjustment jig
(Illuminance: approx. 300 ± 50 lux)
(Used siemens star chart)
Check operation on monitor TV
(Note 2)
Focused at the TELE end and WIDE
end
Procedure
Shoot the chart with the
zoom TELE end.
01
00
Press PAUSE (Write) button.
01
Wait for 3 seconds.
02
01
01
40
13
Press PAUSE (Write) button.
Wait for 1 second.
Check that the lens is
focused while zooming from
TELE end to WIDE end.
Procedure
00
Press PAUSE (Write) button.
00
00
00
00
00
Wait for 3 seconds.
00
9. Black Balance Adjustment
Adjust the black level.
Subject
Measurement Point
Measuring Instrument
Adjustment Page
Adjustment Address
Note 1: If reading/writing data on pages 6E, set data: 06 to
page: 0, address: 10, and then select pages E. By this
data setting, the pages 6E can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to "00".
Note 2: Check that the data of page: 6, address: 02 is "00"
If not, select page: 6, address: 01, set data: 00, and press
the PAUSE (Write) button.
Switch setting
1) POWER ......................................................... CAMERA mode
Adjusting method:
Order Page Address Data
1
0
01
2
6
02
3
6
07
4
6
01
5
6
02
Note 3: The adjustment data will be automatically input to page:
6E, address: C6 to EF.
Processing after Completing Adjustment:
Order Page Address Data
1
6
01
2
0
01
6-29
RadarW
RadarW
RadarW
Not required
Adjusting remote commander
6E
C6 to EF
Procedure
01
Check the data is "00".
Check the data is "04".
Press PAUSE (Write) button.
BF
(Note 3)
Check the data changes to
"01".
Procedure
00
Press PAUSE (Write) button.
00

Advertisement

Table of Contents
loading

Table of Contents