2. Modification of Camera Control Page Data
If the camera control page data has been initialized, change the
data of the "Fixed data-2" address shown in the following table by
manual input.
Modifying Method:
1) Before changing the data, select page: 0, address: 01, and set
data: 01.
2) If 2-digit page is selected, set higher-order digit to page: 0,
address: 10 as data, and then select lower-order digit by a usual
method.
e.g.: Set data: 06 to page: 0, address: 10, and then select page:
D. Thus, the page 6D can be selected.
After the modification of data finished, return the data on page:
0, address: 10 to "00".
3) New data for changing are not shown in the tables because
they are different in destination. When changing the data, copy
the data built in the same model.
Note: If copy the data built in the different model, the cam-
corder may not operate.
4) When changing the data, press the PAUSE button of the ad-
justment remote commander each time when setting new data
to write the data in the non-volatile memory.
5) If all areas were initialized, check that the data at the addresses
for adjustment are initial values (adjustment initial values)
listed in the table. If different, change them to the adjustment
initial values.
6) Select page: 0, address: 01, set data: 01.
7) Select page: 3, address: 71, set data: 01, and press PAUSE
(Write) button.
Processing after Completing Modification Camera Control
Data:
Order Page Address Data
1
0
10
2
3
70
3
3
70
4
2
00
5
2
01
3. 6D Page table
Note 1: If reading/writing data on pages 6D, set data: 06 to page:
0, address: 10, and then select pages: D. By this data
setting, the pages 6D can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to "00".
Note 2: Fixed data-1: Initialized data. (Refer to "1. Initializing
the Camera Control Data")
Fixed data-2: Modified data. (Refer to "2. Modification
of Camera Control Data")
Initial value
Address
NTSC PAL
00 to 59
5A
00
00
5B
5C
36
36
5D
10
10
5E
0B
0B
5F
6E
6E
60 to F9
HVR-Z5C/Z5E/Z5J/Z5N/Z5P/Z5U
Procedure
00
10
Press PAUSE (Write) button.
Check the data changes to
"11".
29
29
Press PAUSE (Write) button.
Remark
Fixed data-1 (Initialized data)
STD gain adj.
Fixed data-1 (Initialized data)
LV Standard data input
MAX gain adj.
Fixed data-1 (Initialized data)
4. 6E Page table
Note 1: If reading/writing data on pages 6E, set data: 06 to page:
0, address: 10, and then select pages: E. By this data set-
ting, the pages 6E can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to "00".
Note 2: Fixed data-1: Initialized data. (Refer to "1. Initializing
the Camera Control Data")
Fixed data-2: Modified data. (Refer to "2. Modification
of Camera Control Data")
Initial value
Address
NTSC PAL
00 to FF
5. 6F Page table
Note 1: If reading/writing data on pages 6F, set data: 06 to page:
0, address: 10, and then select pages: F. By this data set-
ting, the pages 6F can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to "00".
Note 2: Fixed data-1: Initialized data. (Refer to "1. Initializing
the Camera Control Data")
Fixed data-2: Modified data. (Refer to "2. Modification
of Camera Control Data")
Initial value
Address
NTSC PAL
10 to FF
6. 7C Page table
Note 1: If reading/writing data on pages 7C, set data: 07 to page:
0, address: 10, and then select pages: C. By this data set-
ting, the pages 7C can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to "00".
Note 2: Fixed data-1: Initialized data. (Refer to "1. Initializing
the Camera Control Data")
Fixed data-2: Modified data. (Refer to "2. Modification
of Camera Control Data")
Initial value
Address
NTSC PAL
00 to FF
7. 7E Page table
Note 1: If reading/writing data on pages 7E, set data: 07 to page:
0, address: 10, and then select pages: E. By this data set-
ting, the pages 7E can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to "00".
Note 2: Fixed data-1: Initialized data. (Refer to "1. Initializing
the Camera Control Data")
Fixed data-2: Modified data. (Refer to "2. Modification
of Camera Control Data")
Initial value
Address
NTSC PAL
00 to FF
6-16
Remark
Fixed data-1 (Initialized data)
Remark
Fixed data-1 (Initialized data)
Remark
Fixed data-1 (Initialized data)
Remark
Fixed data-1 (Initialized data)

Advertisement

Table of Contents
loading

Table of Contents