Item Name
1
Reset button
2
OA management LAN port
3
UID LED
4
Active OA LED
5
Health LED
6
USB
7
Serial debug port
8
VGA
DVD module LEDs and components
62
Troubleshooting
Description
For the different uses of this button, see the HPE Integrity
Superdome X and Superdome 2 Onboard Administrator User
Guide.
Standard CAT5e (RJ-45) Ethernet port (100/1000Mb) which
provides access to the management subsystem. Access to the
OA's CLI and GUI interfaces, interconnect modules, and iLO
features, such as Virtual Media, requires connection to this port.
Blue = UID on
Indicates which OA is active
Green = OK
Red = Critical error
USB 2.0 Type A connector used for connecting the enclosure DVD
module. Connects to the USB mini-A port on the GPSM.
NOTE:
You must connect the USB cable between the OA module
and the GPSM to ensure proper system functionality.
Serial RS232 DB-9 connector with PC standard pinout.
IMPORTANT:
This port is for OA debug use only, and should not be
connected during normal system operation.
VGA DB-15 connector with PC standard pinout. To access the
KVM menu or OA CLI, connect a VGA monitor or rack KVM
monitor for enclosure KVM.