Malfunctions and fault codes

8.2 Fault code

The electronic controller of the DAIKIN EKHHP shows error
codes on the display. In addition to the error code, the LED on the
controller flashes (see Fig. 8-1).
To delete the error code:
● Press
key for at least 5 s.
If the error arises again:
● Testing and repair by a DAIKIN heating expert.
1
Error code
2
Flashiung LED
Fig. 8-1
Error display
Fault code
Component/description
A1
PCB fault EKHHP
A5
Refrigerant temperature too high
AC
STB Booster-Heater (BSH) has triggered
E1
PCB fault heat pump external unit
E6
Refrigerant compressor blocked
E7
Fan block in the external heat pump unit
E8
Flow rate too high in heat pump external unit
EC
Temperature in internal hot water tank is too high
F3
The discharge temperature from the heat ex-
changer of the external heat pump unit is too high
H0
Sensor refrigerant circuit
H6
Sensor refrigerant compressor
H9
Outside temperature sensor
HC
Components
J3
Temperature sensor discharge refrigerant com-
pressor
L3
Electrical components
L4
Temperature heat exchanger heat pump external
unit too high
L5
Electrical components
P4
Sensor heat exchanger heat pump external unit
defective
U0
Refrigerant loss
U2
Power supply interrupted
U4
Faulty communication heat pump internal unit /
heat pump external unit
U5
Communication error regulator
UA
No communication heat pump internal unit / heat
pump external unit
Tab. 8-2 Possible error codes on the controller of DAIKIN EKHHP