7.3.4 High Output

It is heated to the set hot water temperature as quickly as pos-
sible using a heat pump and integrated electric Booster Heaters
(BSH).
The operating mode "High Output" can be activated if larger hot
water draw-off volumes are required for a short period.
● Press the
key.
Icon
flashes in the controller display.
The output support is automatically deactivated again once the
specified target temperature for hot water is reached.

7.4 Setting the timer programme

The DAIKIN EKHHP can be controlled according to manual set-
tings or according to a freely-programmable timer programme.
A timer programme is not included at the factory.
The user can programme up to 5 switching points for each day to
control the hot water generation and the operating mode (normal,
low noise).
The timer programme is switched on and off using the
Saved time switching points can be changed or deleted at any
time. To have a better overview, we recommend making a record
of the programmed switching times and keeping this in a safe
place.
The user can carry out manual setting changes even if the timer
programme is switched on. The controller always only works ac-
cording to the most recent user parameters set until new param-
eters are set. In this way, manually executed settings are can-
celled by the timer programme at the next active switch time.
The integrated Booster-Heater (BSH) is also controlled fully-au-
tomatically by the controller integrated in the DAIKIN EKHHP.
The switching limits and switching time periods are defined in the
parameter settings. If the Booster-Heater (BSH) is added in, the
controller dispaly shows the symbol
If the DAIKIN EKHHP is in an "OFF" period, the tariff
contacts HT/NT and SG can no longer be evaluated
and thus have no influence on the operation of the
installation.

7.4.1 Display switching times

1. Press the
key.
The current operating mode flashes.
2. Use the
and
keys to select the operating mode to be
programmed.
The selected operating mode flashes.
3. Use the
key to confirm the selection.
The first weekday "MON" is displayed.
4. Use the
and
be programmed.
5. Use the
key to confirm the selection.
The first switching time programmed for the selected
operating mode is displayed.
6. Use the
and
switching times for this operating mode. Empty switching
times are not displayed.
This key
moves you back by one step.
DAIKIN EKHHP(3/5)00AA2V3
DAIKIN Hot water heat pump
008.1423444_05 – 08/2016
key.
.
keys to select the weekday to
keys to move to the other
7
x
Operation, Parameters

7.4.2 Programming switching times

7. Hold the
key pressed for 5 s.
8. Use the
key to select the switching time number.
9. Use the
and
10. By pressing the
key, you can select the type of
switching
for this switching time number.
11. Confirm the switching time and switching type using the
key (press briefly).
12. Repeat steps 8 to 11 to program the other switching times or
to change to the highest switching time of the current day (see
step 6). Then continue with step 13 to complete
programming.
13. Hold the
key pressed for 5 s.
The switching time set is displayed, saved and all switch-
ing times below that are also saved. All switching times
above the current switching time are deleted.
It automatically returns to step 6.
Fig. 7-2
Display and programme switching times

7.4.3 Delete switching time

Delete individual switching times
Deleting one or more programmed switching times is carried out
at the same time as saving the programmed switching times. The
following table explains the procedure.
keys to set the starting time.