Operation, Parameters

7.5.3 Parameter factory settings

0 00 Hot water set temperature for the operating mode "High Output"
01 Hot water set temperature for thermal disinfection
02 Heat retention function switch-on temperature
03 Heat retention switch-off temperature
04 Actvation / deactivation of heat retention function
2 00 Start day thermal disinfection (Legionella protection)
01 Automatic thermal disinfection with hot water heat pump switched on
02 Start time thermal disinfection
03 Automatic thermal disinfection in "Stand-by" mode
04 Holding time thermal disinfection temperature [0-01]
3 00 Automatic restart after a power failure
01 Access authorisation
02 Hot water set temperature >60 °C
4 03 Simultaneous operation of the electrical Booster Heater (BSH) and
heat pump
6 00 Switchng hysteresis of heat pump
01 Heat pump switch-off temperature difference
02 ECO-Timer (BSH)
03 Priority of operating mode "High Output"
04 Steps in the operating mode "Low Noise"
7 00 Behaviour in high/low tariff (HT/NT) - / Smart Grid (SG) mode
01 Switching hysteresis Booster-Heater (BSH) when hot water set tem-
perature is above the maximum possible hot water temperature in
exclusively heat pump mode.
02 Setting Emergency mode (use of BSH permitted or not)
04 Lower external temperature limit for heat pump operation
C 00 Not used
E Display unit information
00 Software version
01 EEPROM version
02 Model ID
These parameters are only accessible in the "Advanced Mode" (see Section 7.5.1).
Tab. 7-5 Overview parameter settings
Installation and operating instructions
30
Parameter name
Standard factory settings
Value
Range
Increment
55
40 - 60
65
50 - 75
40
35 - 55
45
35 - 55
0
0 - 1
FR
every day
0
0 - 1
23:00
0:00 - 23:00
0
0 - 1
10
5 - 60
1
0 - 1
3
2, 3
0
0 - 1
0
0 - 3
14
2 - 20
0
0 - 15
120
5 - 120
1
0 - 1
1
1 - 3
0
0 - 3
2
2 - 20
0
0 - 1
-15
-25 - 10
0
Information value, cannot be changed.
Information value, cannot be changed.
Information value, cannot be changed.
Unit
1
°C
1
°C
1
°C
1
°C
1
0
1:00
h
1
1
Min.
1
1
1
1
1
K
1
K
1
Min.
1
1
1
1
°C
1
1
°C
DAIKIN EKHHP(3/5)00AA2V3