Set-up and installation

4.3 Set-up

CAUTION!
● Only erect the DAIKIN EKHHP when a suffi-
cient ground load-bearing capacity, of
1050 kg/m² plus safety margin, has been
assured. The ground must be flat and level.
● Outdoor installation is not permitted.
● Erection in explosion-risk environments is
not permitted.
● The DAIKIN EKHHP must only be set up in
non-hermetically closed rooms.
● The electronic control system must not be
subjected to atmospheric factors under any
circumstances.
● The storage tank must not be exposed to
continuous direct sunlight, as the UV
radiation and the effects of the weather will
damage the plastic.
● The DAIKIN EKHHP must be installed in a
manner protected from frost.
● Make sure that the supply company does
not provide corrosive domestic water.
– Suitable water treatment may be
required.
WARNING!
The plastic wall of the storage tank of the
DAIKIN EKHHP can melt under the effects of
external heat 80 °C) and, in the extreme case,
can catch fire.
● Erect the DAIKIN EKHHP only at a minimum
distance of 1 m to other heat sources
(>80 °C) (e.g. electric heater, gas heater,
chimney) and flammable materials.
CAUTION!
If the DAIKIN EKHHP is not erected ade-
quately lower the flat solar panels (the top
edge of the of the storage tank is higher than the
bottom edge of the solar panels), the unpres-
surised solar system in the outdoor area will be
unable to drain completely.
● Erect the DAIKIN EKHHP with a DrainBack
solar connection at a sufficient depth to the
flat solar panels (observe the minimum
gradient in the solar connecting lines).
Installation and operating instructions
10
● Remove packing and dispose of it in an environment-friendly
manner.
● Remove the cover plates on the storage tank (Fig. 4-2,
Item B) and unscrew the threaded pieces (Fig. 4-2, Item F)
from the apertures on which the handles are to be mounted.
● Screw handles (Fig. 4-2, Item A) into the threaded holes that
are now free.
A
Handle
B
Cover screen
Fig. 4-2
Attach handles
● Install the DAIKIN EKHHP at the installation site.
– Recommended distances:
To the wall (rear): ≥200 mm.
To the ceiling: ≥200 mm.
– Observe the tilt dimension (see Section 10).
– Carefully transport the DAIKIN EKHHP, use the handles.
– When setting up the unit in a cabinet, behind panels or in
other restricted conditions, sufficient ventilation (e.g.,
using ventilation gratings) must be ensured.
– To avoid a circulation line, install DAIKIN EKHHP close to
the draw-off location.
F
Threaded piece
DAIKIN EKHHP(3/5)00AA2V3
DAIKIN Hot water heat pump
008.1423444_05 – 08/2016