D Command table

Cmd. Sub cmd.
Data
00
see p. 000 Send frequency data (transceive)
01
00
Select LSB (transceive)
01
Select USB (transceive)
02
Select AM (transceive)
03
Select CW (transceive)
04
Select RTTY (transceive)
05
Select FM (transceive)
07
Select CW-R (transceive)
08
Select RTTY-R (transceive)
12
Select PSK (transceive)
13
Select PSK-R (transceive)
02
see p. 000 Read band edge frequencies
03
see p. 000 Read operating frequency
04
see p. 000 Read operating mode
05
see p. 000 Set operating frequency
06
00
Select LSB
01
Select USB
02
Select AM
03
Select CW
04
Select RTTY
05
Select FM
07
Select CW-R
08
Select RTTY-R
12
Select PSK
13
Select PSK-R
07
Select VFO mode
B0
Exchange main and sub bands
B1
Equalize main and sub bands
C0
Turn the dualwatch OFF
C1
Turn the dualwatch ON
D0
Select main band
D1
Select sub band
08
Select memory mode
0001 to
Select memory channel
0099
(0001=M-CH01, 0099=M-CH99)
0100
Select program scan edge channel P1
0101
Select program scan edge channel P2
09
Memory write
0A
Copying memory contents into VFO
0B
Memory clear
0E
00
Scan stop
01
Programmed/memory scan start
02
Programmed scan start
03
F scan start
:
12
Fine programmed scan start
13
Fine
22
Memory scan start
23
Select memory scan start
A1
Select
A2
Select
A3
Select
A4
Select
A5
Select
A6
Select
A7
Select
B0
Set as non-select channel
B1
Set as select channel
( The previously set number by CI-V is set after
turning power ON, or "1" is selected if no selec-
tion is performed.)
01
Set as select channel " 1"
02
Set as select channel " 2"
03
Set as select channel " 3"
B2
00
Set "ALL" for select memory scan
01
Set " 1" for select memory scan
02
Set " 2" for select memory scan
03
Set " 3" for select memory scan
D0
Set scan resume OFF
D3
Set scan resume ON
0F
00
Turn the split function OFF
01
Turn the split function ON
Description
:
F scan start
:
F scan span ±5 kHz
:
F scan span ±10 kHz
F scan span ±20 kHz
:
:
F scan span ±50 kHz
:
F scan span ±100 kHz
:
F scan span ±500 kHz
F scan span ±1 MHz
:
Cmd. Sub cmd.
Data
10
00
Select 10 Hz (1 Hz) tuning step
01
Select 100 Hz tuning step
02
Select 1 kHz tuning step
03
Select 5 kHz tuning step
04
Select 9 kHz tuning step
05
Select 10 kHz tuning step
06
Select 12.5 kHz tuning step
07
Select 20 kHz tuning step
08
Select 25 kHz tuning step
11
00
Send/read attenuator OFF
06
Send/read 6 dB attenuator
12
Send/read 12 dB attenuator
18
Send/read 18 dB attenuator
12
0000
Send/read ANT1 selection (RX ANT OFF)
0001
Send/read ANT1 selection (RX ANT ON)
0100
Send/read ANT2 selection (RX ANT OFF)
0101
Send/read ANT2 selection (RX ANT ON)
13
00
Announce all data with voice synthesizer
01
Announce frequency and S-meter level with
voice synthesizer
02
Announce receive mode with voice synthesizer
14
01
0000 to
Send/read [AF] level
0255
(0000=max. CCW, 0255=max. CW)
02
0000 to
Send/read [RF] level
0255
(0000=max. CCW, 0255=11 o'clock)
03
0000 to
Send/read [SQL] level
0255
(0000=11 o'clock, 0255=max. CW)
06
0000 to
Send/read [NR] level
0255
(0000=0%, 0255=100%)
07
0000 to
Send/read inner [TWIN PBT] position
0255
(0000=max. CCW, 0128=center, 0255=max. CW)
08
0000 to
Send/read outer [TWIN PBT] position
0255
(0000=max. CCW, 0128=center, 0255=max. CW)
09
0000 to
Send/read CW pitch
0255
( 0000=300 Hz, 0128=600 Hz, 0255=900 Hz;
5 Hz steps)
0A
0000 to
Send/read [RF POWER] level
0255
(0000=max. CCW, 0255=max. CW)
0B
0000 to
Send/read [MIC GAIN] level
0255
(0000=max. CCW, 0255=max. CW)
0C
0000 to
Send/read [KEY SPEED] level
0255
(0000=max. CCW, 0255=max. CW)
0D
0000 to
Send/read [NOTCH] position
0255
(0000=max. CCW, 0128=center, 0255=max. CW)
0E
0000 to
Send/read COMP level
0255
(0000=0, 0255=10)
0F
0000 to
Send/read [BK-IN DELAY] position
0255
(0000=max. CCW, 0255=max. CW)
10
0000 to
Send/read [BAL] position
0255
(0000=max. CCW, 0128=center, 0255=max. CW)
12
0000 to
Send/read NB level
0255
(0000=0%, 0255=100%)
14
0000 to
Send/read DRIVE gain
0255
(0000=0%, 0255=100%)
15
0000 to
Send/read Monitor gain
0255
(0000=0%, 0255=100%)
16
0000 to
Send/read VOX gain
0255
(0000=0%, 0255=100%)
17
0000 to
Send/read Anti VOX gain
0255
(0000=0%, 0255=100%)
19
0000 to
Send/read BRIGHT level
0255
(0000=0%, 0255=100%)
15
01
00
Read squelch condition (squelch close)
01
Read squelch condition (squelch open)
02
0000 to
Read S-meter level
0255
(0000=S0, 0120=S9, 0241=S9+60)
11
0000 to
Read RF power meter
0255
(0000=0, 0143=50, 0213=100)
12
0000 to
Read SWR meter
0255
(0000=SWR1.0, 0048=SWR1.5, 0080=SWR2.0)
13
0000 to
Read ALC meter
0255
(0000=0, 0120=Max.)
14
0000 to
Read COMP meter
0255
(0000=0, 0130=15, 0241=30)
12
CONTROL COMMAND
Description
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
151