Viewing Inbound Or Outbound Log Count - Multitech FaxFinder FF240-IP Developer's Manual

Fax over ip server
Hide thumbs Also See for FaxFinder FF240-IP:
Table of Contents

Advertisement

Viewing Inbound or Outbound Log Count

HTTP Request
Line
HTTP Response
Status Codes
Example
1
GET /ffws/v1/outbound_log_count HTTP/1.1
2
content-type: application/xml
3
authorization: Basic YWRtaW46YWRtaW4=
4
-----------------------------------
5
HTTP/1.1 200 OK
6
content-type: application/xml
7
<?xml
version="1.0" encoding="UTF-8"?>
8
<response>
9
<message>Success</message>
10
<log_count>15</log_count>
11
</response>
FaxFinder Web Services API Developer Guide
GET /ffws/v1/outbound_log_count HTTP/1.1
GET /ffws/v1/inbound_log_count HTTP/1.1
200 OK
Shows current T38 configuration.
400 Bad Request
The provided XML is not valid.
LOG FUNCTIONS