Technical Specifications
Technical Specifications
Technical Specifications
The technical specifications for the Cisco IE 4000 switches are as follows:
Table 4
Cisco IE 4000 Technical Specifications
Environmental Ranges
Storage temperature
Operating temperature
Operating humidity
Operating shock
Operating altitude
Storage altitude
Power Requirements
DC input voltage
–40 to 185°F (–40 to 85°C)
1
-40C to +74C
-40C to +70C (Vented Enclosure Operating)
-40C to +60C (Sealed Enclosure Operating)
-34C to +74C (100LFM or more Fan or Blower equipped Enclosure
Operating)
-40C to +85C (Type Tested to +85C for 16 hours)
Note:
If the unit is powered on at subzero temperatures it could take up to 12
minutes to complete the booting process. This is due to the internal heaters
that heat up the devices to safe operating temperature.
5 to 95% (noncondensing)
30 g at 11 ms, and 200 g at 2.11 ms.
Up to 13,000 ft (3962 m)
Up to 40,000 ft (12,192 m)
Maximum operating range: 9.6 to 60 VDC
Nominal: 12, 24, or 48 VDC
Note:
The DC-input power supply is an SELV circuit, and it can only be
connected to another SELV circuit.
Input voltage for power supplies:
PoE mode vs PoE+ input voltages
To power the switch, PWR-IE50W-AC-IEC and PWR-IE50W-AC
provide 24 VDC at 2.1 A.
To support PoE, power supplies PWR-IE65W-PC-AC and
PWR-IE65W-PC-DC provide 54 VDC at 1.2 A.
PoE mode: 48 VDC (nominal)/44-57 VDC (absolute range)
PoE+ mode: 54 VDC (nominal)/50-57 VDC (absolute range)