Global Arming; Global Arming Notes; Global Arm; Global Disarm - Honeywell VISTA-128BPT User Manual

Commercial burglary partitioned security system with scheduling
Hide thumbs Also See for VISTA-128BPT:
Table of Contents

Advertisement

• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •
The Global Arming option may be assigned for use by some users. If Global Arming was enabled for
use with your security code, a keypad prompt (message) shown below appears after pressing one of
the arming function keys (STAY, INSTANT, AWAY, MAXIMUM, OFF).
ARM P12345678
HIT 0-8 XXX--X --
G l o b a l A r m i n g N o t e s

Global Arm

When performing a Global Arm, if there are faults in any of the selected partitions, the system will
enter a Summary Mode. Faulted zones in all the selected partitions will be displayed. These faults must
be corrected or bypassed. This Summary Mode will end in approximately 120 seconds if no keys are
pressed.

Global Disarm

When performing a Global Disarm, if any of the selected partitions has a condition which would cause
the keypad to beep (e.g., alarm memory or a trouble condition), the system enters a Summary Mode
and displays the condition.
NOTE: This Summary Mode will end in approximately 120 seconds if no keys are pressed.
Section 7: Global Arming
The prompt displays all the partitions. The user may only
arm/disarm the partitions they are assigned access to.
To select the partition(s) that are to be armed (or disarmed),
enter the desired number 1-8. An "X" will appear under that
partition. Entering a partition's number again will delete the "X"
and that partition will not arm when this prompt is exited.
NOTE: Pressing 0 will turn all partitions the user is assigned
access to On/Off.
When completed, press ∗ to exit. All the partitions with the "X"
will then arm/disarm.