The whole screen is shown below. The creating methods for fixed text and Bit Button components for
[Open], [Stop] and [Close] garage door operations are the same as that of [1 Wait].
a Screen b Fixed Texts c Bit Lamp d Function Keys e Bit Button components
Bit Lamp Components
The states of the [OPEN], [STOP] and [CLOSE] switches are shown by the lamp.
The property settings for Bit Lamp are:
Corresponding
Name
Read Address
Function
Label
Graphics
Function Key Components
These are used for switching to [6 Check 1] and [8 Check 3] screens.
The property settings for the Function Key components are:
Screen Name
Function Key
Label
Graphics
[8 Check 3]
The [8 Check 3] screen will be displayed when the screen-switching button on the
[7 Check 2] screen is pressed.
Configure functions below:
• Fixed text indicating the garage door state.
• Number Display components displaying the current values of TIM0 and CNT0 used in the ladder
program.
• Function Key components, buttons for switching to [7 Check 2] and [1 Wait] screens.
• Bit Button components, allocated to [Open], [Stop] and [Close] garage door operations respectively.
NB-series Programmable Terminals Startup Guide Manual(V109)
a
b
d
c
OPEN Switch
W_bit 1.00
W_bit 1.01
Normal
Transport font:
Transport font:
0: blank
0: blank
1: OPEN
1: STOP
Use the vector graphic: Lamp2State1-00.vg
Previous Screen
Change Screen[6 Check 1]
Transport font:
0: Previous Screen
1: Previous Screen
Use the vector graphic: CTRL_BAR001.vg
STOP Switch
CLOSE Switch
W_bit 1.02
Transport font:
0: blank
1: CLOSE
Next Screen
Change Screen[8 Check 3]
Transport font:
0: Next Screen
1: Next Screen