4 Screen Creation
2
Bit Button component for Open/Stop/Close
Function: After the component is pressed, the bits set as write address is set to ON, and then is
reset. The write addresses for each component is shown in the table below.
The property settings are:
Component Name
Write Address
Bit Button Type
Graphics
Fixed Text
Select the "Text" button on the draw toolbar and set the property of fixed text.
Level Meter Component
The function of the Level Meter Component is to indicate numbers of flash of headlights detected.
The times of flash are related to the current value of the ladder program counter. Up to 3 times of
flash can be counted when the maximum value of the Level Meter is set to "3".Put fixed texts [1], [2]
and [3] above the Level Meter as the scale to indicate times of flash.
Select [Level Meter] from [Parts], drag it to the edit window after selecting it with a single-click.
4-16
Open
W_bit 1.00
Reset switch
Use the vector graphic:
Up.vg (A vector graphic
created by user, which
is an upward arrow)
Determined by OS language.
Stop
W_bit 1.01
Use the vector graphic:
Middle.vg (A vector
graphic created by user,
which is a square)
NB-series Programmable Terminals Startup Guide Manual(V109)
Close
W_bit 1.02
Use the vector graphic:
Down.vg (A vector
graphic created by user,
which is an downward
arrow)