BICO
The following types of connectable parameters are available. A description of BICO
technology is given in the functions chapter.
Table 5-1
BICO
BI
BO
CI
CO
CO/BO
Access level
The access level is controlled using parameter P0003. In this case, only those parameters
are visible at the OP, where the access level is less than or equal to the value assigned in
parameter P0003. On the other hand, for STARTER, only access levels 0 and 3 are relevant.
For example, parameters with access level 3 cannot be changed if the appropriate access
level has not been set.
The following access levels are implemented in the SINAMICS G120 inverter units:
Table 5-2
Access level
0
1
2
3
4
Note
In STARTER, all of the user parameters (access stage 3) are always displayed using the
expert list – for the setting p0003 = 0, 1, 2 or 3.
When changing parameters using STARTER, or via a high-level control system, parameter
value changes always become immediately effective.
Control Units CU240S
Operating Instructions, 11/2006, A5E00766042B AA
Parameter attributes - BICO
Description
Binector Input
Binector Output
Connector Input
Connector Output
Connector Output/Binector Output
Parameter attributes - access level
Description
User-defined parameter list (refer to P0013)
Standard access to the most frequently used parameters
Extended access, e.g. to inverter I/O functions
Expert access only for experienced users
Service access only for authorized service personnel – with password
protection.