8. Keep control knob pressed in for 30 sec-
onds after lighting pilot. After 30 seconds,
release control knob.
• If control knob does not pop out when
released, contact a qualified service
person or gas supplier for repairs.
NOTE: If pilot goes out, repeat steps 4
through 8.
9. Slightly push in and turn control knob
counterclockwise
position.
10. Wait one minute and switch selector
switch to the ON position to light burners
(see Figure 52). When using in the ON
position (without remote) burners will
light on high. There is no adjustment to
the fl ames without using remote.
11. To leave pilot lit and shut off burners only,
turn control knob clockwise
PILOT position, or use remote control
manual OFF button, or set selector switch
in the OFF po si tion.
WARNING: Make sure the se-
lector switch is in the OFF position
when you are away from home for
long periods of time. Appliance
will come on automatically with
selector switch in the ON position.
ON REMOTE OFF
Figure 52 - Remote Selector Switch in
ON Position
Pilot
Burner
Igniter
Electrode
Figure 53 - Pilot (Natural/ Propane/LP)
26
OPERATION
Continued
1. Turn control knob clockwise
OFF position.
2. Set selector switch in the OFF position.
3. Close equipment shutoff valve (see Fig-
ure 14, Page 15).
to the ON
1. Follow steps 1 through 6 under Lighting
Instructions, Page 25.
2. Depress control knob and light pilot with
match.
3. Keep control knob pressed in for 30 sec-
onds after lighting pilot. After 30 seconds,
release control knob. Now follow steps 9
through 11 under Lighting Instructions,
Page 25.
to the
.
WARNING: This fi replace has
a three-prong, grounded electri-
cal plug. This plug helps protect
you against electrical shock.
Only connect plug to a properly
grounded, three-prong recep-
tacle. Do not cut or remove the
grounding prong from this plug.
PRG
Locate the blower switch by opening lower
louver on fi replace. Blower switch is located
at lower center inside louver door.
NOTE: It is safe to operate fi replace with blower
turned off. However, the blower helps distribute
heated air from the fi replace.
NOTE: Periodically check the louvers of the
fi rebox and remove any dust, dirt or other
obstructions.
SuperiorFireplaces.us.com
TO TURN OFF GAS
TO APPLIANCE
MANUAL LIGHTING
PROCEDURE
BLOWER
OPERATION
to the
126817-01D