8-3. Temporary Operation
• Temporary Auto operation, existence of Auto
Restart, and Temporary Cooling operation can be
set by the RESET button of the indoor controller.
Fig. 8-3-1
Table 8-3-1
RESET button
OFF → ON
Temporary Auto operation start
After pushing button
for 3 seconds
After pushing button
for 10 seconds
8-3-1. Temporary Auto Operation
• When the RESET button is pushed, the Auto
operation with set temperature fixed at 25°C starts.
Controlling is same as that of Auto operation by
the remote controller.
• When the RESET button is pushed again, the
operation stops.
• During Temporary Auto operation, operation by the
remote controller is accepted.
• Using the Auto Restart function, the Temporary
Auto operation starts when power failure is reset.
8-3-2. Temporary Cooling Operation
• When the RESET operation button keeps pushed
for 10 seconds, Cooling operation of which com-
pressor motor speed and the indoor fan speed are
fixed starts.
Compressor motor speed :
13 : 30 rps
Indoor fan speed : Low
• When the TRESET operation button is pushed
again, the operation stops.
• Auto Restart function is unavailable.
Control
Auto Restart control select
Temporary Cooling
operation start
– 36 –