Electrical connection

Electrical connection
All work on the electrical
connection must be carried out by a
Miele service technician or a
qualified electrician.
– The electrical installation must be in
compliance with current local and
national safety regulations.
– The plug connection must comply
with national regulations. (The
electrical outlet must be accessible
after the appliance has been
installed.) This facilitates access for
electrical safety checks, for example
when the appliance is being repaired
or serviced.
– If the appliance is hard wired, a
multiple-pole circuit breaker must be
installed. The contact opening at the
main breaker must be at least 3 mm
wide and lockable in the open
position.
– For increased safety, it is
recommended that the machine be
connected upstream to a ground fault
circuit interrupter with a trip current of
30 mA.
– Equipotential bonding should be
carried out if required.
– The power cord may only be
replaced by an original Miele spare
part.
– For technical data, see the data plate
or wiring diagram supplied.
The commercial dishwasher must only
be operated with the voltage, frequency
and fuse rating shown on the data
plate.
62
This machine can be converted to a
different type of power supply in
accordance with the conversion
diagram and wiring diagram supplied.
The data plates are at the back of the
commercial dishwasher and along the
right edge of the open door.
The commercial dishwasher is supplied
with a wiring diagram.
The conversion diagram is attached to
the base panel behind the plastic base
cover.