Henny Penny EVOLUTION ELITE EEE-142 Operator's Manual page 61

Reduced oil capacity open fryer
Hide thumbs Also See for EVOLUTION ELITE EEE-142:
Table of Contents

Advertisement

6-1. SPECIAL PROGRAm
mODE (Continued)
Aug. 2011
SP-24 • Serial No. of Fryer
SP-25 • Change Mgr. Code- 1 = YES
SP-26 • Change Usage Code - 1 = YES
SP-27 • Dispose Requires Code ? - YES or NO
SP-28 • Longer Fill Time Enabled - YES or NO
SP-29 • Let User Exit Fill? - YES or NO
SP-30 • Skip 'SKIM' Prompt? - YES or NO
SP-31 • 2-Stage Wash Enabled? - YES or NO
Press and hold the button for 5 seconds until "LEVEL 2"
followed by, "SP PROG" and "ENTER CODE" show in the
display.
Enter code 1,2,3, and "SP-1" "TEMP" "FORMAT" show in
the displays.
If a bad code is entered, a tone sounds and "BAD CODE"
shows on the display. Wait a few seconds, the controls
revert back to the cook mode, and repeat the above steps.
To exit from the Special Program Mode at any time, press
and hold
button for 2 seconds.
Degrees Fahrenheit or Celsius (SP-1)
The left display flashes "SP-1" and "TEMP", "FORMAT".
Press the
or
• Use button to go back to previous menu items
• Press button when finished with current Level 2 step
Language (SP-2)
Press
button and "SP-2" and "LANGUAGE" flash on
the left display. Press the
the desired language.
System Initialization (SP-3)
Press
button and "SP-3" and "DO SYSTEM INIT"
flash in the display, along with "INIT" on the right display.
To reset the controls to factory default settings, press and
hold √ button and control counts down "IN 3", "IN2", "IN
1". Once display shows "-INIT-" & *DONE* the controls
are reset to factory defaults.
56
Model EEE-141, 142, 143, 144
buttons to choose ºF or ºC.
or
buttons to select

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents