List Of Parameters; Parameters Of Electronic Board Inputs/Outputs; User Parameters (Utt); Installer Parameters - Riello NexPro Plus Installation And Maintenance Manual

Table of Contents

Advertisement

3 .6 List of parameters

3 .6 . 1 Parameters of electronic board inputs/outputs

Starting from the current water temperature display, by pressing
information on machine status, such as probe temperature, inputs/outputs status, runtime (see Navigation diagram). The access to
this branch is indicated by the steady illumination of a point on the right end of the display.
To exit the display mode, press and hold
t=60sec from the last release of
Parameter
Default Status
1 open (alarm)
ID1
0
0 close
ID2
0
0 close
1 enabled
ID3
0
0 standby
1 standby
ID4
0
0 enabled
S01
-
-
S02
-
-
S03
-
-
S04
-
-
1 enabled
r1
-
0 disabled
1 enabled
r2
-
0 disabled
1 enabled
r3
-
0 disabled
1 enabled
r4
-
0 disabled
1 enabled
r7
-
0 disabled
r8
-
-

3 .6 .2 User parameters (Utt)

User parameters are the setpoints set in the different operating modes. From the selected operating mode, press
key to display the setpoint set. Press again
without pressing any other key; the setpoint flashes for several seconds and the display shows the water temperature detected by
the probe S01.
Parameter
Default Limits
Ut1
55
15-H01
Ut2
55
15-H27
Ut3
55
Ut1-H01
Ut4
60
(Ut1+H28-2)-60

3 .6 .3 Installer parameters

The access to installer parameters is indicated by LED L12 on.
To access branches CFn, dFr, Fan, ALL, EXV follow the navigation diagram (see "3.7 Navigation diagram" on pege 18).
The route of each branch is cyclical: the first variable can be reached from the last one and vice versa by pressing
[DOWN] keys.
Inside each branch, by pressing and holding
the parameter to be changed has been detected:
− press
[SET] key to display its value
− press
[UP] or
[DOWN] keys to change its value
− press
[SET] key again to confirm the change and go back to the parameter display.
From any position inside the navigation diagram, press and hold
To go back from the parameter selection inside a branch to the selection of branches CFn, dFr, Fan, ALL, EXV press and hold [SET] key
until a beep is emitted, then release.
For the Installer branch parameters an access password is required (default parameter H18 = 000).
To exit, press and hold
[SET] key (about 10 seconds); otherwise the display mode is interrupted after a time t=60sec from the last
release of
[UP],
[DOWN] or
the second method does not store any change to the variable.
[SET] key (about 10 seconds); otherwise the display mode is interrupted after a time
[UP],
[DOWN] or
[SET] keys.
Description
High pressure
Low pressure preset
Electrical heater remote ON/OFF
Unit remote ON/OFF
Water temperature probe
Outdoor air temperature probe
Evaporator intake temperature probe
Evaporator output temperature probe
Compressor ignition enabling
Electrical heater ignition enabling
Fan ignition enabling
Solenoid valve enabling
Volt-free contact for boiler enabling
Electronic expansion valve opening steps
[UP] or
[DOWN] keys to change the parameter; the change is automatically confirmed
Unit
Description
°C
Accumulation tank water setpoint in AUTO operation
°C
Accumulation tank water setpoint in MANUAL operation
Accumulation tank water setpoint in FAST HEATING MODE (AUTO
°C
only)
°C
Accumulation tank water setpoint inHIGH TEMPERATURE MODE
[UP] and
[DOWN] keys, it is possible to scroll quickly the variables displayed. Once
[SET] keys. The first method confirms any parameter change made with
[SET] key it is possible to display the
[SET] key to go back and display the current water temperature.
15
STARTING AND USE
Type
Digital input
Digital input
Digital input
Digital input
Analogue input
Analogue input
Analogue input
Analogue input
Relay output
Relay output
Relay output
Relay output
Digital output
Digital output
[UP] or
[DOWN]
Level
0
0
0
0
[UP] and
[UP] and
[DOWN] keys,