Graco 3A4803A Operation, Parts page 26

Brushless cordless handheld airless sprayers
Table of Contents

Advertisement

Common Procedures
5.
Securely tighten cup cover onto cup
support.
6.
Align VacuValve on cup cover with
Prime Pump/Spray knob. Push cup
assembly onto sprayer and twist to lock.
7.
Install battery onto sprayer.
8.
Make certain the Prime Pump/Spray
knob is in the Prime Pump position
(pointed down). Set speed control to 10.
26
9.
Turn the sprayer upside down and point
the sprayer into a waste pail. Pull the
trigger for three seconds.
10. Turn Prime Pump/Spray knob forward to
SPRAY position. Rotate spray tip 180
degrees to UNCLOG position.
ti29719a
11. While holding the sprayer upside down
point the sprayer into a waste pail. Pull
the trigger for three seconds.
ti30556a
IMPORTANT! For best results, do not spray
more than one cup of water through the tip
while cleaning. If more flushing is needed,
remove the tip from the sprayer to avoid
excessive wear.
12. Sprayer is now flushed and ready for
use. See Start Up, page 11.
SPRAY
UNCLOG
ti29739a
3A4803A

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents