Program the BW500 as follows:
P390 = 1
P391-01 = 6.94
P391-02 = 13.89
P391-03 = 20.83
P391-04 = 27.78
P391-05 = 34.72
P392-01 = - 10.7
P392-02 = 11.1
P392-03 = - 5.1
P392-04 = 8.7
P392-05 = -6.0
Note:Often only one point of compensation is required, usually at a low load value. In the prior exam-
ple, if compensation was only required at 6.94 kg/m, the programming could be as follows. Compen-
sation is optimized by establishing the next load value that agrees with the material test, hence where
compensation is zero and entering it as the next compensation point.
P390 = 1
P391-01 = 6.94
P391-02 = 20.00
P392-01 = -10.7
P392-02 = 0
BW500 and BW500/L
Operating Instructions, 12/2016, A5E33482052-AD
Parameter
Function
linearization – on
point 1, load
point 2, load
point 3, load
point 4, load
point 5, load
point 1, compensation
point 2, compensation
point 3, compensation
point 4, compensation
point 5, compensation
linearization on
point 1, load
point 2, load
point 1, compensation
point 2, compensation