Parameters
12.3 mA I/O Parameters (P200 - P220)
Value
14
a)
15
a)
16
a)
Not available with BW500/L.
a)
Entry:
Note
Before you can use Online Calibration, P100, P255, P355, P356, and P357 must be set up.
0 = OFF
1 = alternate display
2 = reset totalizer 1
3 = zero
4 = span
5 = print
6 = multispan selection
7 = reserved
8 = reset batch
9 = PID freeze
10 = PID setpoint source
11 = PID mode
12 = external alarm
13 = remote communication write
14 = Initiate Online Calibration
15 = Accept new online calibration span
16 = Auxiliary speed sensor
If the BW500 is programmed for multispan operation, the auxiliary input contact state
1)
determines the multispan number (equivalent to P365). Input 1 is reserved for multispan 1 and 2
selection. Input 2 is reserved for multispan 3 and 4 selection. Input 3 is reserved for multispan 5
to 8 selection.
Not available with BW500/L
2)
166
Function
initiate online calibra-
tion:
accept new online cali-
bration span:
auxiliary speed sensor
f
1) 2)
2)
2)
2)
2)
2)
2)
2)
Symbol
2) 3)
Operating Instructions, 12/2016, A5E33482052-AD
Description
momentary closure of
the input contact initi-
ates online calibration
momentary closure of
the input contact ac-
cepts the online calibra-
tion deviation
for differential speed
detection
BW500 and BW500/L