as indicated by the BW500. The following data was tabulated. (This example is exaggerated for
emphasis).
The material tests should be run at same belt speed, representative of normal operation; in this
case 1.2 m/s. For each rate, record the corresponding load value by scrolling to the BW500 load
display during running conditions or by calculation.
load = (rate/speed)
calculation example: % compensation = [(2.5 – 2.8) x 100]/2.8
a)
= -10.7
BW500 and BW500/L
Operating Instructions, 12/2016, A5E33482052-AD
BW500 load
material test
kg/m
6.94
13.89
20.83
27.78
34.72
BW500 total
tonnes
tonnes
2.5
5.0
7.5
10.0
12.5
7.7 Linearization
compensation
2.8
-10.7
4.5
11.1
7.9
-5.1
9.2
13.3
-6.0
Recalibration
a)
%
8.7
93