When attaching the pressure roller lever to the lower fusing unit assembly, attach the spring between the
pressure roller lever and fusing unit first. If you try to attach the spring after attaching the pressure roller
lever to the fusing unit, it is difficult to install the spring.
Thermistor and Thermostat
Thermostat
1. Upper fusing unit assembly (
2. Thermostat [A] ( x 2)
• Do not touch the thermostat with your hands.
• Do not re-use a thermostat that is already opened. Safety is not guaranteed if you do this.
Thermistor
1. Upper fusing unit assembly (
p.43 "Hot Roller and Fusing Lamp")
p.43 "Hot Roller and Fusing Lamp")
Fusing
4
49