3. Preventive Maintenance

User Maintenance

The customer can do all PM items with the Maintenance Kit.
Meter-charge mode must be set to "disabled" (engine SP mode 5930).
Cross-reference: "Engine service mode" in the Appendices.
The Operation panel shows "Replace Maintenance Kit" when the PM counter gets to 90K. After the user
replaces the fusing unit in the maintenance kit, the machine automatically resets the PM counter.
Item
Fusing unit
Transfer roller
Paper feed roller
Friction pad
PSU Fan Filter
Quantity
1
1
3
For standard and optional tray(s)
3
For standard and optional tray(s)
1
Remarks
3