Counter Location; Minimum Airflow Clearance - Cornelius QUEST ELITE 4000 Installation Manual

Hide thumbs Also See for QUEST ELITE 4000:
Table of Contents

Advertisement

Select a location in a well ventilated area, close to a grounded electrical outlet. If possible do not place the unit
close to hot and/or steaming machines.
M
A
INIMUM
IRFLOW
The minimum airflow clearance is: 4" (10.16 cm) in back and 12" (30.48 cm) on top and open to the front.
!
IMPORTANT:
Condenser air is drawn in from the bottom of the rear panel and discharged out the top of the rear panel.
Failure to maintain clearance space will reduce capacity of the unit and cause premature compressor
failure.
The Dispenser needs to be placed using 4inch legs that are included.
MINIMUM 12'' AIR
CLEARANCE AT TOP
© 2010-2016, Cornelius Inc.

COUNTER LOCATION

C
LEARANCE
Figure 5. Minimum Clearances
MINIMUM 4'' AIR FLOW
CLEARANCE AT BACK
AND 4'' AT SIDES
- 7 -
Quest Elite 4000 Installation Manual
Publication Number: 620048956INS