EverFocus EMV800 HD User Manual page 166

8 / 12 channels mobile dvr
Table of Contents

Advertisement

Output Type: Select an output type when an alarm is triggered.
Timeout: Select this option and then set up the Timeout Duration in the field below, the
alarm output will last for the setup duration time (10 ~ 150 seconds).
Permanent: Alarm will remain active until the user presses the "Enter" key on the IR
Remote Control or resets the alarm remotely.
Transparent: Alarm output remains as long as the alarm input is active.
Trans + Timeout: Alarm output continues until event ends, then continues for the setup
duration time (10 ~ 150 seconds).
Timeout Duration: This function only appears when you select Timeout or Trans + Timeout
options in the Output Type drop-down list. Select a duration time for the motion event. The
alarm output will last for the setup duration time between 10 and 150 seconds.
Main Monitor/Call Monitor: Select Full Screen to force the camera which detects motion to
display full screen on the monitor. The full screen camera view will last according to the
Output Type selected in the field above.
Edit Motion Grid: Press the button to bring up the Motion Setting menu. To edit the motion
grids, please refer to the instructions later in this section.
Apply To: Click the button to apply the same settings to the desired cameras.
Save: Click to save the settings.
To Edit the Motion Grids:
1.
Click the Edit Motion Grid button, the Motion Setting menu appears.
EMV800 HD / EMV1200 HD Mobile DVR
156

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Emv1200 hd

Table of Contents