Sony HVR-M10C Service Manual page 326

Table of Contents

Advertisement

2-2-3.
INITIALIZATION OF 9, 1D PAGE DATA
< Changed contents (Page 6-62) >
2. Modification of 9, 1D Page Data
If the 9, 1D page data has been initialized, change the data of the
"Fixed data-2" address shown in the following table by manual input.
Modifying Method:
1)
Before changing the data, select page: 0, address: 01, and set
data: 01.
2)
When changing the 9 page data, select page: 0, address: 10,
and set data: 00.
3)
When changing the 1D page data, select page: 0, address: 10,
and set data: 01.
After completing the modification of 1D page data, reset the
data of this address to "00".
4)
New data for changing are not shown in the tables because
they are different in destination. When changing the data, copy
the data built in the same model.
Note: If copy the data built in the different model, the camcorder may
not operate.
5)
When changing the data, press the PAUSE button of the
adjustment remote commander each time when setting new
data to write the data in the non-volatile memory.
6)
Check that the data of adjustment addresses is the initial value.
If not, change the data to the initial value.
Processing after Completing Modification of 9, 1D Page data
Order Page Address Data
1
0
10
2
2
00
3
2
01
Version check of the SP control microprocessor:
(VC-367 board IC8601)
Order Page Address Data
1
0
10
2
04
FF
HVR-M10C/M10E/M10J/M10N/M10P/M10U
Procedure
00
Set the data.
29
Set the data.
29
Set the data, and press PAUSE
button.
Procedure
00
Set the data.
The data shows the version of the
SP control microprocessor.
23: Ver. 4.0 (MP4)
24: Ver. 5.0 (MP5)
25: Ver. 6.0 (MP6)
28: Ver. 7.0 (MP7)
4. 1D Page Table
Note1: When reading or writing the 1D page data, select page: 0, address:
10, and set data: 01, then select D page. The 1D page can be chosen
by this data setting.
After reading or writing, reset the data of page: 0, address: 10 to
"00".
Note2: Fixed data-1: Initialized data. (Refer to "1. Initializing the 9, 1D
Page Data".)
Fixed data-2: Modified data. (Refer to "2. Modification of 9, 1D
Page Data").
Note3: When the SP control microprocessor is replaced, check that the
data of the fixed data address shown in the table is the initial value.
If not, change the data to the initial value.
Note4: SP control microprocessor ver. 4.0 (MP4).
Note5: SP control microprocessor ver. 5.0 (MP5) or ver. 6.0 (MP6) or
ver. 7.0 (MP7).
Address
Address
Initial value
Initial value
00 to 2C
2D
00 (Note4)
E7 (Note5)
2E
00 (Note4)
F9 (Note5)
2F to FF
— 12 —
: Changed portion
: Added portion
Remark
Remark
Fixed data-1
Fixed data
Fixed data-1
Table. 6-2-13.