1-3-8.
Retainer Plate
1. Removal procedure
1)
Remove LED 1 from the retainer plate.
Remove the two screws (special head screw M1.4 × 2.0) 2.
2)
3)
Release the four claws B, C, D and E, and remove the
retainer plate 3 in the direction of the arrow mark F.
4)
Release the claw A and remove the reel lock release 4.
4 Reel lock release
Claw A
REEL LOCK RELEASE
Key Points
in Re-assembling
The reel lock release should not be re-used.
The retainer plate must not have any deformation.
The reel lock release should be fully installed.
(Should not be left in the half-installed state.)
HVR-M10C/M10E/M10J/M10N/M10P/M10U
1 LED
2. Attachment procedure
1) Install the reel lock release 4.
2) Place the retainer plate 3 on top of the LS chassis block assy
and engage the four claws in the order starting from E, D, C
and B.
Install the two screws (special head screw M1.4 × 2.0) 2 in
3)
the order starting from G then H.
Tightening torque: 0.059 ± 0.01N•m (0.6 ± 0.1kgf•cm)
4) Install LED 1 to the retainer plate.
2 Two screws
(M1.4 × 2.0)
H
Claw B
Claw C
RETAINER PLATE
Key Points
in Re-assembling
All claws must be fully engaged.
(Caution : No claws should be left disengaged.)
The flexible board should not be pinched by anything.
The retainer plate must not touch with the MIC terminal.
6-18
3 Retainer plate
G
F
Claw E
Claw D

Advertisement