Appendix
Using the Indicate LDL button
Ê Shut down and power off the server.
Ê Disconnect the AC power cords from the system.
I
It is mandatory to disconnect power cords in order to use the Indicate
LDL functionality.
Ê Remove the air duct as described in section
on page
91.
Ê Press the Indicate LDL button (1) to highlight defective components.
Onboard indicators
The LEDs have the following meaning:
LED
A - Identification
B - CSS
(Customer Self
Service)
C - GEL
(Global Error
LED)
552
Indicator
Meaning
The server has been highlighted using
ServerView Operations Manager, iRMC web
blue on
frontend or the ID button on the front panel
for easy identification
The server has been highlighted for easy
blue flashing
identification using the iRMC (AVR) with
disabled local VGA output.
off
No critical event detected (CSS component).
orange on
Prefailure event detected (CSS component).
orange flashing CSS component failure detected.
No critical event detected (non CSS
off
component).
Prefailure event detected (non CSS
orange on
component).
Non CSS component failure detected.
Possible causes:
– System is out of the specified
orange flashing
– Defective sensor
– CPU error
– Error detected by server management
Upgrade and Maintenance Manual
"Removing the system air duct"
temperature range
software
TX2560 M2 / RX2560 M2